Page 1
GIRA Observer 180 plus Info Installation Instructions Observer 180 plus Order No.: 0830 02 Theory of Operation This observer responds to thermal movement initiated by persons, animals or objects and, when detecting, turns on consumers such as lights. The unit remains activated as long as movements are detected. Otherwise, the observer switches off after a preset delay time has elapsed.
GIRA Observer 180 plus Info Installation Instructions Detection field size: 16 m x 32 m, please refer to the illustration. The different grey zones in the illustration identify the three observation levels. The three observation levels are defined as follows: Near range from 0 m to approx.
Page 3
GIRA Observer 180 plus Info Installation Instructions Do not touch the sensor window. Do not align the sensor window towards the sun. Sensors will be damaged by the high thermal energy. Install the observer in a vibration-free manner as sensor movements may also initiate switching.
Page 4
GIRA Observer 180 plus Info Installation Instructions For installation at building corners use the 'corner piece' (optional) accessory item. Attach observer connection enclosure to corner piece central screw , then mount the corner piece to the building corner with two screws.
GIRA Observer 180 plus Info Installation Instructions Additional Functions The mode can be changed via a mechanical flush-mounted push- button (normally closed contact) (for connecting the push-button, ZEIT SENS. Time please refer to the wiring diagrams). 1 min 5 min...
GIRA Observer 180 plus Info Installation Instructions Intelligent Limit Function Once the observer has switched on, the brightness is no longer evaluated. The lamps shine on the brightness sensor, the preset brightness value might be exceeded, and the observer would switch off.
GIRA Observer 180 plus Info Installation Instructions Example : Masked area. : Observed area. To mask the remote area, cut out the lower aperture blades only. Example : Masked area. : Observed area. If the detection angle of 180° is not required because of the local conditions, the detection field should be restricted by the use of the slip-fit aperture.
GIRA Observer 180 plus Info Installation Instructions If no push-button for the additional functions has been installed for the 180° observer, the test mode can also be set on the unit. Select the following for the function test: ZEIT Time SENS.
Page 9
GIRA Observer 180 plus Info Installation Instructions Deactivating the Observer Remove the observer from operation with switch S1 or S2. When the observer is re-activated, switch S1 triggers a switching process, whereas S2 does not. S1 S2 BK (black): BU (blue): ↓...
GIRA Observer 180 plus Info Installation Instructions Specifications Rated working range: 16 m Installation height: Approx. 2.40 m Rated voltage: 230 VAC, 50 Hz Switching contact: Relay Starting current: Max. 20 A Automatic cut-out: 10 A Switching capacity: Incandescent lamps...
Page 11
GIRA Observer 180 plus Info Installation Instructions A Few Remarks on the Working Range The Optical System and its Alignment With its many optical lenses, the observer "looks" slantwise down from its place of installation. At the specified installation height of 2.4 m,...
Page 12
GIRA Observer 180 plus Info Installation Instructions Depending upon the atmospheric humidity, the temperature change is transmitted to the observer well or with some losses. Good transmission of the thermal radiation (e. g. dry air) ensures a stable working range.
GIRA Observer 180 plus Info Installation Instructions Acceptance of guarantee We accept the guarantee in accordance with the corresponding legal provisions. Please return the unit postage paid to our central service department giving a brief description of the fault: Gira Giersiepen GmbH &...