Observer 180 plus
Info
Installation Instructions
Observer 180 plus
Theory of Operation
This observer responds to thermal movement initiated by persons, animals or objects and, when
detecting, turns on consumers such as lights.
The unit remains activated as long as movements are detected. Otherwise, the observer switches off
after a preset delay time has elapsed.
A visual signal indicates the responding of the unit.
With the aid of an adjustable twilight switch, the switching function is activated from a desired
brightness value only or can be set to day-time/night-time operation.
The working range of the unit can be individually adapted by adjusting the sensitivity.
Via a mechanical flush-mounted push-button (normally closed contact), the mode can be changed:
Observer mode.
Light ON for 2 hours.
Light OFF for 2 hours.
Test mode.
1
Observer 180 plus
The working range of the unit can be reduced by a sensitivity
control.
A protective film
weather-proof and dependable as well as guarantees a high quality
standard.
2
Detection Field
The observer has a dense, semicircular detection field consisting
of three levels with 144 switching segments.
28/99
Order No.: 0830 02
in front of lens system
makes the units
Page: 1 of 13

Advertisement

Table of Contents
loading

Summary of Contents for Gira 180 plus

  • Page 1 GIRA Observer 180 plus Info Installation Instructions Observer 180 plus Order No.: 0830 02 Theory of Operation This observer responds to thermal movement initiated by persons, animals or objects and, when detecting, turns on consumers such as lights. The unit remains activated as long as movements are detected. Otherwise, the observer switches off after a preset delay time has elapsed.
  • Page 2: Choosing The Location

    GIRA Observer 180 plus Info Installation Instructions Detection field size: 16 m x 32 m, please refer to the illustration. The different grey zones in the illustration identify the three observation levels. The three observation levels are defined as follows: Near range from 0 m to approx.
  • Page 3 GIRA Observer 180 plus Info Installation Instructions Do not touch the sensor window. Do not align the sensor window towards the sun. Sensors will be damaged by the high thermal energy. Install the observer in a vibration-free manner as sensor movements may also initiate switching.
  • Page 4 GIRA Observer 180 plus Info Installation Instructions For installation at building corners use the 'corner piece' (optional) accessory item. Attach observer connection enclosure to corner piece central screw , then mount the corner piece to the building corner with two screws.
  • Page 5: Additional Functions

    GIRA Observer 180 plus Info Installation Instructions Additional Functions The mode can be changed via a mechanical flush-mounted push- button (normally closed contact) (for connecting the push-button, ZEIT SENS. Time please refer to the wiring diagrams). 1 min 5 min...
  • Page 6: Using The Slip-Fit Aperture

    GIRA Observer 180 plus Info Installation Instructions Intelligent Limit Function Once the observer has switched on, the brightness is no longer evaluated. The lamps shine on the brightness sensor, the preset brightness value might be exceeded, and the observer would switch off.
  • Page 7: Function Test

    GIRA Observer 180 plus Info Installation Instructions Example : Masked area. : Observed area. To mask the remote area, cut out the lower aperture blades only. Example : Masked area. : Observed area. If the detection angle of 180° is not required because of the local conditions, the detection field should be restricted by the use of the slip-fit aperture.
  • Page 8: Wiring Diagrams

    GIRA Observer 180 plus Info Installation Instructions If no push-button for the additional functions has been installed for the 180° observer, the test mode can also be set on the unit. Select the following for the function test: ZEIT Time SENS.
  • Page 9 GIRA Observer 180 plus Info Installation Instructions Deactivating the Observer Remove the observer from operation with switch S1 or S2. When the observer is re-activated, switch S1 triggers a switching process, whereas S2 does not. S1 S2 BK (black): BU (blue): ↓...
  • Page 10: Specifications

    GIRA Observer 180 plus Info Installation Instructions Specifications Rated working range: 16 m Installation height: Approx. 2.40 m Rated voltage: 230 VAC, 50 Hz Switching contact: Relay Starting current: Max. 20 A Automatic cut-out: 10 A Switching capacity: Incandescent lamps...
  • Page 11 GIRA Observer 180 plus Info Installation Instructions A Few Remarks on the Working Range The Optical System and its Alignment With its many optical lenses, the observer "looks" slantwise down from its place of installation. At the specified installation height of 2.4 m,...
  • Page 12 GIRA Observer 180 plus Info Installation Instructions Depending upon the atmospheric humidity, the temperature change is transmitted to the observer well or with some losses. Good transmission of the thermal radiation (e. g. dry air) ensures a stable working range.
  • Page 13: Acceptance Of Guarantee

    GIRA Observer 180 plus Info Installation Instructions Acceptance of guarantee We accept the guarantee in accordance with the corresponding legal provisions. Please return the unit postage paid to our central service department giving a brief description of the fault: Gira Giersiepen GmbH &...

Table of Contents