1
Safety instructions
Electrical devices may only be mounted and connected by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the devise or load. In
so doing, take all the circuit breakers into account, which support dangerous voltages to the
device and or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage. The load
is not electrically isolated from the mains even when the device is switched off.
Do not press on the sensor window. Device can be damaged.
The device is not suitable for use as a burglar alarm or other alarm.
These instructions are an integral part of the product, and must remain with the end customer.
2
Intended use
Automatic switching of lighting depending on the heat motion and ambient brightness
Operation with flush-mounted insert for dimming or switching or 3-wire extension
Wall installation on flush-mounted insert
Product characteristics
Extension of the detection area in combination with 3-wire extension
Operation with 2-wire or 3-wire extension, rotary dimmer extension or push-button
Selectable brightness threshold
Selectable sensitivity
Fixed run-on time
Switch on with last saved brightness or saved switch-on brightness, with dimming insert
Switch-on brightness can be saved permanently via extension, with dimming insert
Dimming light via extension with dimming insert
Motion detector cover 1.10 m
Screen for limiting the detection area
Automatic operation
The device detects heat motions of people, animals and objects.
The light is switched on if a person enters the detection area and the brightness is below
the set threshold.
The run-on time restarts with each detected motion.
The light is switched off, if:
no more movement is detected in the detection area and the run-on time has elapsed or
the ambient light is too bright and the run-on time has elapsed.
To avoid any switch-on caused by a cooling illuminant, no movement signals are evaluated for a
brief lockout time after switching off. The motion detector adjusts itself to the ambient conditions
to keep the time as short as possible.
32599602
10865947
04.05.2018
1 / 9

Advertisement

Table of Contents
loading

Summary of Contents for Gira 5373 Series

  • Page 1 System 3000 Motion detector top unit 1.10 m Standard, Motion detector top unit 2.20 m Standard Motion detector top unit 1.10 m Standard Order no.: 5373 .. Motion detector top unit 2.20 m Standard Order no.: 5375 .. User manual Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons.
  • Page 2: Operation

    System 3000 Motion detector top unit 1.10 m Standard, Motion detector top unit 2.20 m Standard Behaviour after a mains voltage failure After mains voltage return, the device performs a self-test for a maximum of 60 seconds. After the self-test has been completed, the device is ready for operation. The following applies during the self-test: –...
  • Page 3: Fitting And Electrical Connection

    System 3000 Motion detector top unit 1.10 m Standard, Motion detector top unit 2.20 m Standard 4.1 Fitting and electrical connection Motion detection The detection of heat sources through a motion detector and thus the extent of the detection field is influenced by the following criteria: Geometry of the detection field, assembly height and set sensitivity (Figure 1) up to (Figure 8) Direction of movement: If motion detector passes tangentially, this results in a heat signal which can be evaluated well.
  • Page 4 System 3000 Motion detector top unit 1.10 m Standard, Motion detector top unit 2.20 m Standard Figure 3: Range with radial direction of motion motion detector cover 1.10 m 25% sensitivity 50% sensitivity 75% sensitivity 100% sensitivity Motion detector cover 2.20 m detection field and range Figure 4: Motion detector cover 2.20 m detection field and installation height Figure 5: Range with tangential direction of motion motion detector cover 2.20 m, mounting height 2.20 m...
  • Page 5 System 3000 Motion detector top unit 1.10 m Standard, Motion detector top unit 2.20 m Standard 75% sensitivity 100% sensitivity Figure 6: Range with radial direction of motion motion detector cover 2.20 m, mounting height 2.20 m 25% sensitivity 50% sensitivity 75% sensitivity 100% sensitivity Figure 7: Range with tangential direction of motion motion detector cover 2.20 m, mounting...
  • Page 6 System 3000 Motion detector top unit 1.10 m Standard, Motion detector top unit 2.20 m Standard Figure 8: Range with radial direction of motion motion detector cover 2.20 m, mounting height 1.10 m 25% sensitivity 50% sensitivity 75% sensitivity 100% sensitivity Selecting installation location ■...
  • Page 7: Technical Data

    System 3000 Motion detector top unit 1.10 m Standard, Motion detector top unit 2.20 m Standard Figure 10: Mount the cover at 90° 4.2 Commissioning Make settings The adjusters for the brightness threshold and sensitivity are located on the rear of the motion detector cover.
  • Page 8: Troubleshooting

    Please submit or send faulty devices postage paid together with an error description to your re- sponsible salesperson (specialist trade/installation company/electrical specialist trade). They will forward the devices to the Gira Service Center. They will forward the devices to the Gira Service Center.
  • Page 9 System 3000 Motion detector top unit 1.10 m Standard, Motion detector top unit 2.20 m Standard Gira Giersiepen GmbH & Co. KG Elektro-Installations- Systeme Industriegebiet Mermbach Dahlienstraße 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel +49(0)21 95 - 602-0 Fax +49(0)21 95 - 602-191 www.gira.de...

This manual is also suitable for:

5375 series

Table of Contents