Rotating Gobo Replacement:
The fixture is supplied with 8 rotating, replaceable gobos. See below for installation instructions.
1) Disconnect and isolate from power and wait for the unit
to cool, place the fixture on a flat surface and unscrew the
thumbscrews on the gobo access door.
3) Carefully push the gobo holder you are wanting to
replace upwards, away from the gobo wheel.
5) Push the gobo holder back into
the slot in the gobo wheel and push
towards to gobo wheel to ensure it is
seated correctly.
www.prolight.co.uk
2) Remove the gobo access door (this is connected to the
main chassis with an earth wire, do not disconnect this).
4) Pull the gobo holder out of the unit. Now you can remove
the circlip, followed by the gobo from the gobo tray. Replace
the gobo and fit the circlip back into the tray.
6) Move the gobo access door back
into position over the gobo access
slot, ensuring the earth wire isn't
obstructing any mechanisms.
Helix Scan XP 150W Scanner User Manual
Gobo replacement
7) Tighten both thumbscrews to
secure the gobo access door.