Valcom V-2006A User Manual

Valcom V-2006A User Manual

Integrated six zone paging control unit, integrated six zone handsfree talkback paging control unit
Hide thumbs Also See for V-2006A:

Advertisement

V-2006A - INTEGRATED SIX ZONE PAGING CONTROL UNIT
V-2006AHF - INTEGRATED SIX ZONE HANDSFREE
TALKBACK PAGING CONTROL UNIT
"WARNING: To reduce the risk of fire or
electric shock, do not expose this equipment
to rain or moisture."
"WARNING: Shock Hazard - Do Not Open."
"AVIS: Risque de Choc Electrique ne pas
Ouvrir."
"PELIGRO: Corriente Electrica - No Abra."
"CAUTION: To reduce the risk of fire replace
only with same type 2A, 125V fuse. 2A, 125V
may be replaced by a 1A, 250V provided
voltage selector is set for 230V."
"DANGER: Afin de réduire le risque de feu,
remplacez le fusible par le même type de
fusible à 2A, 125V. On peut utiliser un
fusible à 1A, 250V pourvu que le sélecteur
ďalimentation soit fixé sur 230V. Ne pas
ouvrir."
"VORSICHT: Zur verringerung von
feuergefahr die sicherung nur mit derselben
type 2A, 125V ersetzen. Statt 2A, 125V Kann
1A, 250V Benutzt werden, vorausgesetzt, die
spannung ist auf 230V eingestellt. Nicht
öffnen."
"PELIGRO: Para reducir el peligro de
incendio remplazarlo unicamente con un
fusible del mismo tipo 2A, 125V. El fusible
de 2A, 125V podra ser remplazado por uno
de 1A, 250V si el selector de voltaje esta
puesto en 230V. No abres."

SPECIFICATIONS

Purpose
The V-2006A is an Integrated Six Zone Paging Control
Unit. It provides six individual zones of one-way paging,
plus three programmable zone groups and all call. The
built-in -24VDC power supply provides 1.5 Amps.
The V-2006AHF is an Integrated Six Zone Handsfree
Talkback Paging Control Unit. It provides six
individual zones of talkback and/or one-way paging, plus
three programmable zone groups and all call.
Nominal Specifications
Zone Audio Outputs:
One-Way: Will supply audio for up to 150 Valcom
one-way self-amplified speakers per Zone
Handsfree:
Will supply audio for up to 2 Talkback Speakers plus
40 one-way speakers per zone
Input Impedance:
Input Level:
Music Source Impedance:
Music Source Level:
Speaker Output Impedance:
Output Level:
DC Power Output:
Power Requirements:
Tone Activation:
Clock Tone – Dry Contact
Night Ring Tone – Dry Contact
or Ring Voltage
K5 and K6 Relay Contacts:
1
VSP-V-2006A/2006AHF
Issue 10
600 Ohms
-10dBm minimum
8 to 600 Ohms
-10 to -18dBm
8 Ohm (1 way)
-10dBm (1 way)
1 Watt (talkback)
-24VDC at 1.5 Amps
115VAC 2 Amps or
230VAC @ 1 Amp
(slo-blo)
-90VAC (20 to 30Hz)
Rated 1 Amp @
125VAC
2 Amps @ 30VDC
947207

Advertisement

Table of Contents
loading

Summary of Contents for Valcom V-2006A

  • Page 1: Specifications

    Nominal Specifications Zone Audio Outputs: • One-Way: Will supply audio for up to 150 Valcom one-way self-amplified speakers per Zone • Handsfree: Will supply audio for up to 2 Talkback Speakers plus 40 one-way speakers per zone •...
  • Page 2: System Operation

    Access Methods • Electronic Key System (C. O. Line Position) PABX (Loop or Ground Start Trunk) • • 1A2 Key Systems (400 Type Line Card required) • 600 Ohms Page port equipped with contact closure and DTMF dialing capability • Dedicated single line telephone Additional Equipment Required •...
  • Page 3: Installation

    Inhibit Option (Meet Me Answer) The V-2006A/V-2006AHF is equipped with an inhibit feature that automatically mutes output to the speakers and allows a handset conversation between the paging party and a single line telephone connected to the paging Tip and Ring. A single line telephone modified for "A"...
  • Page 4: Optional Connections

    Connection of One-Way Amplified Speakers See Figure 1, 66 Block Diagram. NOTE: The V-2006A/V-2006AHF provides external power of 30 power units (1.5 Amps of -24VDC) to operate amplified speaker assemblies. Additional power supplies are required for speakers using power over the 30 power units. When using additional power supplies, make certain: The -24VDC outputs are not connected to each other.
  • Page 5 Roanoke, VA. Should repairs be necessary, attach a tag to the unit clearly stating your company name, address, phone number, contact person and the nature of the problem. Send the unit to: Valcom, Inc. Repair and Return Dept. 5614 Hollins Road Roanoke, VA 24019-5056...
  • Page 6: Programming Instructions

    PROGRAMMING FEATURE CHART FEATURES Handsfree (with V-2006AHF only) Background Music Night Ring Clock Tones Included in Group #1 Included in Group #2 Included in Group #3 Included in All Call PROGRAM EXAMPLE: Zone 6 Programmed for One-Way Paging, Background Music, Night Ring, Clock Tones, Not in Group 1-2 or 3 and All Call. PROGRAMMING INSTRUCTIONS System programming is non-volatile and is not affected by power outages .
  • Page 7: Troubleshooting Chart

    Not Working Valcom, Inc. warrants its products to be free from defects in materials and workmanship under conditions of normal use and service for a period of one year from the date of shipment. The obligation under this warranty shall be limited to the replacement, repair or refund of any such defective device within the warranty period, provided that: inspection by Valcom, Inc.
  • Page 8 Station Port To Loop or Ground Start Trunk Override Contact Closure (Page Port) VALCOM AMPLIFIED SPEAKER VALCOM RING AMPLIFIED -24 VDC SPEAKER (Ground strap required for Ground Start access) RING -24 VDC VALCOM 45 ohm TALKBACK SPEAKERS (V-2006AHF only)
  • Page 9 Voltage Select Switch SW3 DIP SWITCH OPTIONS K6 Relay K6 relay operates whenever zone 6 is in use K5 Relay K5 relay operates for 2.2 seconds when the * is pressed when any zone accessed Fuse Battery Backup Molex Connector AC Connector This side of the V-2006A/V-2006AHF oriented toward floor.

This manual is also suitable for:

V-2006ahf

Table of Contents