Njoy Astris 5K/3P2T2 User Manual page 39

Table of Contents

Advertisement

Available languages

Available languages

1.If the alarm occurs accidentally, the inverter can generate power, which may
cause the power grid to cause the inverter to automatically recover. No extra
B2-Leakage
action is needed.
current
2.If the alarm occurs frequently, and is accompanied by an insulation impedance
abnormal
alarm. Check the abnormal alarm of the insulation.
3. If the alarm continues, the equipment cannot generate electricity, please
contact the customer service report repair
1.If occurs when the light is weak(such as the early morning or evening, and the
extreme weather of rain and dust storms), the component voltage is lower than
B4-PV under
normal, No extra action is needed.
voltage
2.If there is a weak condition of light, please check the group to have a short
circuit and open circuit or not
B5-PV
Normal phenomena under light weak conditions. No extra action is needed.
irradiation
weak
B7-PV string
Check and modify the positive and negative polarity of the input of the circuit
reverse
string
1. If the alarm occurs occasionally, the inverter can be automatically recovered
C0-Internal
and no action is required.
power supply
2. If the alarm occurs repeatedly, the inverter cannot work properly. Please
abnormal
contact the customer service center.
1. If the alarm occurs occasionally, the inverter can be automatically recovered
C2-Inverter over
and no action is required.
dcbias current
2. If the alarm occurs repeatedly, the inverter cannot work properly. Pls.contact
the customer service center
1. If the alarm occurs occasionally, the inverter can be automatically recovered
and no action is required.
C3-Inverter
2.If the alarm occurs repeatedly, the single-phase inverter, please check
relay
whether the live line and zero line of the contact connection is reversed; the
abnormal
three-phase inverter check the live line to zero line and the voltage of the
live line to the ground. If the grid side is normal, please contact the customer
service report repair.
1. If the alarm occurs occasionally, the inverter can be automatically restored,
no action required.
C5-Inverter over
2. If the alarm occurs repeatedly, pls. check the installation site for direct
temperature
sunlight, good ventilation, and high ambient temperature (Such as installed
on the parapet). If the ambient temperature is lower than 45° C and the heat
dissipation is good, contact the customer service center.
1. If the alarm occurs occasionally, it could have been an occasional exception
to the external wiring, the inverter can be automatically recovered, no action
C6-GFCI
required.
abnormal
2. If it occurs repeatedly or cannot be recovered for a long time, pls.contact
customer service to report repair.
C7-System type
If the alarm occurs, the inverter can not work, pls. restart the inverter If the
error
alarm continues, pls.contact customer service to report repair.t