INSTALLATIoN
Commissioning
High limit safety cut-out
Note
At temperatures below –15 °C the high limit safety cut-out
may respond. The appliance may be subjected to these
temperatures during storage or transport.
f Check whether the high limit safety cut-out has tripped.
f
HSBC 200
HSBC 200 S
1 High limit safety cut-out reset button
www.stiebel-eltron.com
13.2 Commissioning the heat pump manager
Commission the heat pump manager and make all settings in
accordance with the operating and installation instructions for
the heat pump manager.
Note
For DHW mode, ensure that the PARALLEL OPERATION
option is set in the heat pump manager. With this setting
the primary pump is also active in DHW mode.
To set the heat pump manager:
f With the MENU key, call up the main menu.
f
f Select the menu or value and confirm with OK:
f
1
SETTINGS
DHW
Note
On appliances with a single phase connection, set the
heat pump manager as follows for calculating the amount
of heat.
To set the heat pump manager:
f With the MENU key, call up the main menu.
f
f Select the menu or value and confirm with OK:
f
1
SETTINGS
HEATING
Area cooling setting
Material losses
!
Condensation caused by the temperature falling below
the dew point can lead to material losses. HSBC is there-
fore exclusively approved for area cooling.
Adjusting the heat pump manager settings for area cooling:
f With the MENU key, call up the main menu.
f
f Select the menu or value and confirm with OK:
f
SETTINGS
COOLING
STANDARD SETTING
DHW MODE
ELECTRIC REHEATING
NUMBER OF STAGES
COOLING
STANDARD SETTING
COOLING CAPACITY
ACTIVE COOLING
AREA COOLING
SET FLOW TEMPERATURE
FLOW TEMP HYSTERESIS
SET ROOM TEMPERATURE
Value
PARALLEL OPERATION
Value
2
Value
ON
system specific
ON
system specific
system specific
system specific
HSBC |
49