STIEBEL ELTRON HSBC 200 S Operation And Installation

STIEBEL ELTRON HSBC 200 S Operation And Installation

Hide thumbs Also See for HSBC 200 S:

Advertisement

OPERATION AND INSTALLATION
Integral cylinder
» HSBC 200 S (AU)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HSBC 200 S and is the answer not in the manual?

Questions and answers

Summary of Contents for STIEBEL ELTRON HSBC 200 S

  • Page 1 OPERATION AND INSTALLATION Integral cylinder » HSBC 200 S (AU)
  • Page 2: Table Of Contents

    - The safety valve discharge aperture must remain Maintenance ������������������������������������������������ 21 open to atmosphere. Specification ������������������������������������������������ 22 16.1 Dimensions and connections  22 16.2 Wiring diagram  24 16.3 Data table  26 GUARANTEE ENVIRONMENT AND RECYCLING | HSBC 200 S (AU) www.stiebel-eltron.com...
  • Page 3: General Information

    Failure to observe this information will result in serious injury or death. WARNING Failure to observe this information may result in serious injury or death. CAUTION Failure to observe this information may result in non-seri- ous or minor injury. www.stiebel-eltron.com HSBC 200 S (AU) |...
  • Page 4: Safety

    Multifunction assembly (MFG) - WPL 15-25 AC (S), WPL 15-25 A (S) The multifunction assembly switches between heating circuit and - WPL 19/24 IK DHW heating. - WPL 07-17 ACS classic - HPA-O 7-13 (C/S/CS) Premium | HSBC 200 S (AU) www.stiebel-eltron.com...
  • Page 5: Settings

    If the consumption indicator changes colour from white to red, have the signal anode checked by a qualified con- tractor and if necessary replaced. 1 White = Anode OK 2 Red = Requires checking by qualified contractor www.stiebel-eltron.com HSBC 200 S (AU) |...
  • Page 6: Installation

    - Pump assembly for a heating circuit with mixer HSBC-HKM - Remote control for heating operation - High limit safety cut-out STB-FB - Pressure hoses - Water softener HZEA The minimum side clearances can be swapped to left or right. | HSBC 200 S (AU) www.stiebel-eltron.com...
  • Page 7: Transport And Handling

    Separating the appliance sections f Remove the screw at the top in the middle of the appliance. f Unhook the front casing towards the top. f Pull the “heating sensor” out of the buffer cylinder. www.stiebel-eltron.com HSBC 200 S (AU) |...
  • Page 8: The Appliance May Be Used By Children Aged

    Pull the hydraulic connectors off forwards. f Remove the 4 hydraulic hoses and the insulation segment. 1 Handle f Tip the upper section of the appliance backwards. Use the handle for improved grip. | HSBC 200 S (AU) www.stiebel-eltron.com...
  • Page 9 Lay the sensor lead in the guide groove provided for this pur- 2 Guide pin pose in the insulation segment. 3 Dotted line (perforation in the panel) 4 Guide groove 5 Positioning aid www.stiebel-eltron.com HSBC 200 S (AU) |...
  • Page 10: Installation

    Remove the union nut at the mixed heating return thermal insulation. connection. f Also protect all supply lines/cables against humidity, damage and UV radiation by means of a conduit. f Connect the hydraulic connections with flat gaskets. | HSBC 200 S (AU) www.stiebel-eltron.com...
  • Page 11 Replace the dummy plugs with the enclosed plastic fixing aids at the mixed heating flow and return connections. f Fit the pump assembly connection pipes. 1-2 Nm f When installing the servomotor, ensure the drive cam is po- sitioned correctly. www.stiebel-eltron.com HSBC 200 S (AU) |...
  • Page 12: Dhw Connection And Safety Assembly

    Ensure that the safety valve drain hose is open to the outside. f Lay the safety valve drain hose with a constant fall to the drain. f Secure the drain hose to prevent any hose movement while water is discharged. | HSBC 200 S (AU) www.stiebel-eltron.com...
  • Page 13: Filling The System

    (see chapter “Specifi- cation / Data table”). If necessary reduce the flow rate at the butterfly valve of the safety assembly. f Carry out a tightness check. f Check the safety valve. www.stiebel-eltron.com HSBC 200 S (AU) |...
  • Page 14: Venting The Appliance

    Close the quick-action air vent valve again after venting. f Route all power cables and sensor leads into the appliance through the cable entry. f Connect the power cables and sensor leads as detailed below. | HSBC 200 S (AU) www.stiebel-eltron.com...
  • Page 15: Electric Emergency/Booster Heater And Control Voltage

    Electric emergency/booster heater (DHC) Connected Cable Terminal assignment load cross-section 2.9 kW 2.5 mm² 5.9 kW 2.5 mm² 2.5 mm² f Connect the cables for the electrical emergency/booster heater with the desired rating as in the table. www.stiebel-eltron.com HSBC 200 S (AU) |...
  • Page 16 Earth X1.18 CAN (connection for FET remote control and CAN B ISG Internet Service Gateway) X1.19 CAN (connection for heat pump and WPE heat CAN A pump extension)     AA01 (WPM) | HSBC 200 S (AU) www.stiebel-eltron.com...
  • Page 17 In the case of temporary faults, the output switches the signal through for a specific time. In the case of faults that result in a permanent appliance shutdown, the output switches through permanently. www.stiebel-eltron.com HSBC 200 S (AU) |...
  • Page 18: Sensor Installation

    With the FE 7 remote control you can adjust the set room tempera- ture for heating circuit 1 or heating circuit 2 by ± 5 °C in automatic mode only. You can also select the operating mode. f Connect the remote control to terminal AA01-X1.13. | HSBC 200 S (AU) www.stiebel-eltron.com...
  • Page 19: Commissioning

    ACTIVE COOLING … …… AREA COOLING … ……… SET FLOW TEMPERATURE system specific … ……… FLOW TEMP HYSTERESIS system specific … ……… SET ROOM TEMPERATURE system specific 1 High limit safety cut-out reset button www.stiebel-eltron.com HSBC 200 S (AU) |...
  • Page 20: Circulation Pumps Wilo-Para

    ∆p-c Constant speed, pump curve III Q/m³/ h Constant differential pressure ∆p-c Constant speed (*) Pressing the button for the 9th time returns to the basic set- ting (constant speed / characteristic curve III). | HSBC 200 S (AU) www.stiebel-eltron.com...
  • Page 21: Appliance Handover

    Before any work on the appliance, disconnect all poles of the appliance from the power supply. Replacing the signal anode f Replace the signal anode if it becomes depleted. Draining the buffer cylinder f Drain the buffer cylinder via the drain valve. www.stiebel-eltron.com HSBC 200 S (AU) |...
  • Page 22: Specification

    Female thread Rp 1 DHW circulation Male thread G 1/2 Safety assembly drain Diameter T&P valve Female thread Rp 3/4 Heat pump flow Diameter Heat pump return Diameter Heating flow Diameter Heating return Diameter | HSBC 200 S (AU) www.stiebel-eltron.com...
  • Page 23 Sensor heat pump Diameter cooling, optional Sensor DHW Diameter Sensor heating Diameter Flange Diameter Pitch circle diameter Screws M 10 Torque Protective anode 16.1.1 HSBC-HKM accessories HSBC-HKm Heating flow, mixed Diameter Heating return, mixed Diameter www.stiebel-eltron.com HSBC 200 S (AU) |...
  • Page 24: Wiring Diagram

    KF22 Relay, booster heater MFG AA07 PCB, booster heater MFG XD01.1 Terminal, power supply EB01 Booster heater MFG (not for HSBB/HSBC 200 S BE) XD01.2 Terminal, power-OFF contact BF01 Flow rate and temperature, heating circuit XD02 Terminal, MFG power supply...
  • Page 25 (X2.14.1 Mixer OPEN/X2.14.2 Mixer CLOSE) AA07-X71 Not assigned AA01-X2.15 Connector, mixer, heating circuit 3 (X2.15.1 Mixer OPEN/X2.15.2 Mixer CLOSE) AA07-X72 Connector, CAN bus AA06-X27 Terminal, programming unit EB01-X59 Terminal, MFG AA07-X60 Connector, temperature sensor, heat pump flow BT01 www.stiebel-eltron.com HSBC 200 S (AU) |...
  • Page 26: Data Table

    2 x B 16 Frequency Versions IP-Rating IP20 Values T&P valve, nominal set pressure 0,85 T&P valve, nominal set temperature °C Dimensions Height 1908 Width Depth Height of unit when tilted 2107 Weights Weight (wet) Weight (dry) | HSBC 200 S (AU) www.stiebel-eltron.com...
  • Page 27 Specification Further details HSBC 200 S (AU) 200024 Maximum altitude for installation 2000 www.stiebel-eltron.com HSBC 200 S (AU) |...
  • Page 28 Who gives the warranty where our subsidiaries sell our products a guarantee can only The warranty is given by Stiebel Eltron (Aust) Pty Ltd be issued by those subsidiaries. Such guarantee is only grant- (A.B.N. 82 066 271 083) of 294 Salmon Street, Port Mel- ed if the subsidiary has issued its own terms of guarantee.
  • Page 29 12.7. An unauthorised person has modified, serviced, repaired test the unit. or attempted to repair the unit without our consent. 12.8. Non genuine parts other than those manufactured or ap- proved by us have been used on the unit. www.stiebel-eltron.com HSBC 200 S (AU) |...
  • Page 30 The Stiebel Eltron warranty for the unit is in addition to any rights and remedies you may have under the Australian Consumer Law.
  • Page 31 NOTES www.stiebel-eltron.com HSBC 200 S (AU) |...
  • Page 32 Deutschland Verkauf Tel. 05531 702-110 | Fax 05531 702-95108 | info-center@stiebel-eltron.de STIEBEL ELTRON GmbH & Co. KG Kundendienst Tel. 05531 702-111 | Fax 05531 702-95890 | kundendienst@stiebel-eltron.de Dr.-Stiebel-Straße 33 | 37603 Holzminden Ersatzteilverkauf Tel. 05531 702-120 | Fax 05531 702-95335 | ersatzteile@stiebel-eltron.de Tel.