- The safety valve discharge aperture must remain Maintenance ������������������������������������������������ 21 open to atmosphere. Specification ������������������������������������������������ 22 16.1 Dimensions and connections 22 16.2 Wiring diagram 24 16.3 Data table 26 GUARANTEE ENVIRONMENT AND RECYCLING | HSBC 200 S (AU) www.stiebel-eltron.com...
Failure to observe this information will result in serious injury or death. WARNING Failure to observe this information may result in serious injury or death. CAUTION Failure to observe this information may result in non-seri- ous or minor injury. www.stiebel-eltron.com HSBC 200 S (AU) |...
If the consumption indicator changes colour from white to red, have the signal anode checked by a qualified con- tractor and if necessary replaced. 1 White = Anode OK 2 Red = Requires checking by qualified contractor www.stiebel-eltron.com HSBC 200 S (AU) |...
- Pump assembly for a heating circuit with mixer HSBC-HKM - Remote control for heating operation - High limit safety cut-out STB-FB - Pressure hoses - Water softener HZEA The minimum side clearances can be swapped to left or right. | HSBC 200 S (AU) www.stiebel-eltron.com...
Separating the appliance sections f Remove the screw at the top in the middle of the appliance. f Unhook the front casing towards the top. f Pull the “heating sensor” out of the buffer cylinder. www.stiebel-eltron.com HSBC 200 S (AU) |...
Pull the hydraulic connectors off forwards. f Remove the 4 hydraulic hoses and the insulation segment. 1 Handle f Tip the upper section of the appliance backwards. Use the handle for improved grip. | HSBC 200 S (AU) www.stiebel-eltron.com...
Page 9
Lay the sensor lead in the guide groove provided for this pur- 2 Guide pin pose in the insulation segment. 3 Dotted line (perforation in the panel) 4 Guide groove 5 Positioning aid www.stiebel-eltron.com HSBC 200 S (AU) |...
Remove the union nut at the mixed heating return thermal insulation. connection. f Also protect all supply lines/cables against humidity, damage and UV radiation by means of a conduit. f Connect the hydraulic connections with flat gaskets. | HSBC 200 S (AU) www.stiebel-eltron.com...
Page 11
Replace the dummy plugs with the enclosed plastic fixing aids at the mixed heating flow and return connections. f Fit the pump assembly connection pipes. 1-2 Nm f When installing the servomotor, ensure the drive cam is po- sitioned correctly. www.stiebel-eltron.com HSBC 200 S (AU) |...
Ensure that the safety valve drain hose is open to the outside. f Lay the safety valve drain hose with a constant fall to the drain. f Secure the drain hose to prevent any hose movement while water is discharged. | HSBC 200 S (AU) www.stiebel-eltron.com...
(see chapter “Specifi- cation / Data table”). If necessary reduce the flow rate at the butterfly valve of the safety assembly. f Carry out a tightness check. f Check the safety valve. www.stiebel-eltron.com HSBC 200 S (AU) |...
Close the quick-action air vent valve again after venting. f Route all power cables and sensor leads into the appliance through the cable entry. f Connect the power cables and sensor leads as detailed below. | HSBC 200 S (AU) www.stiebel-eltron.com...
Electric emergency/booster heater (DHC) Connected Cable Terminal assignment load cross-section 2.9 kW 2.5 mm² 5.9 kW 2.5 mm² 2.5 mm² f Connect the cables for the electrical emergency/booster heater with the desired rating as in the table. www.stiebel-eltron.com HSBC 200 S (AU) |...
Page 16
Earth X1.18 CAN (connection for FET remote control and CAN B ISG Internet Service Gateway) X1.19 CAN (connection for heat pump and WPE heat CAN A pump extension) AA01 (WPM) | HSBC 200 S (AU) www.stiebel-eltron.com...
Page 17
In the case of temporary faults, the output switches the signal through for a specific time. In the case of faults that result in a permanent appliance shutdown, the output switches through permanently. www.stiebel-eltron.com HSBC 200 S (AU) |...
With the FE 7 remote control you can adjust the set room tempera- ture for heating circuit 1 or heating circuit 2 by ± 5 °C in automatic mode only. You can also select the operating mode. f Connect the remote control to terminal AA01-X1.13. | HSBC 200 S (AU) www.stiebel-eltron.com...
ACTIVE COOLING AREA COOLING SET FLOW TEMPERATURE system specific FLOW TEMP HYSTERESIS system specific SET ROOM TEMPERATURE system specific 1 High limit safety cut-out reset button www.stiebel-eltron.com HSBC 200 S (AU) |...
∆p-c Constant speed, pump curve III Q/m³/ h Constant differential pressure ∆p-c Constant speed (*) Pressing the button for the 9th time returns to the basic set- ting (constant speed / characteristic curve III). | HSBC 200 S (AU) www.stiebel-eltron.com...
Before any work on the appliance, disconnect all poles of the appliance from the power supply. Replacing the signal anode f Replace the signal anode if it becomes depleted. Draining the buffer cylinder f Drain the buffer cylinder via the drain valve. www.stiebel-eltron.com HSBC 200 S (AU) |...
2 x B 16 Frequency Versions IP-Rating IP20 Values T&P valve, nominal set pressure 0,85 T&P valve, nominal set temperature °C Dimensions Height 1908 Width Depth Height of unit when tilted 2107 Weights Weight (wet) Weight (dry) | HSBC 200 S (AU) www.stiebel-eltron.com...
Page 27
Specification Further details HSBC 200 S (AU) 200024 Maximum altitude for installation 2000 www.stiebel-eltron.com HSBC 200 S (AU) |...
Page 28
Who gives the warranty where our subsidiaries sell our products a guarantee can only The warranty is given by Stiebel Eltron (Aust) Pty Ltd be issued by those subsidiaries. Such guarantee is only grant- (A.B.N. 82 066 271 083) of 294 Salmon Street, Port Mel- ed if the subsidiary has issued its own terms of guarantee.
Page 29
12.7. An unauthorised person has modified, serviced, repaired test the unit. or attempted to repair the unit without our consent. 12.8. Non genuine parts other than those manufactured or ap- proved by us have been used on the unit. www.stiebel-eltron.com HSBC 200 S (AU) |...
Page 30
The Stiebel Eltron warranty for the unit is in addition to any rights and remedies you may have under the Australian Consumer Law.
Page 31
NOTES www.stiebel-eltron.com HSBC 200 S (AU) |...
Need help?
Do you have a question about the HSBC 200 S and is the answer not in the manual?