Details On Energy Consumption; Data Table - STIEBEL ELTRON HSBC 200 Operation And Installation Manual

Integral cylinder
Hide thumbs Also See for HSBC 200:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 32
INSTALLATIoN
Specification

16.4 Details on energy consumption

Product datasheet: DHW cylinder to regulation (EU) no. 812/2013
Manufacturer
Supplier's model identifier
Energy efficiency class
Standby losses
Cylinder capacity

16.5 Data table

Hydraulic data
Nominal capacity, DHW cylinder
Nominal capacity, buffer cylinder
Surface, indirect coil
Content, indirect coil
External available pressure differential, circulation pump / heat pump at 1.0 m³/h
External available pressure differential, circulation pump / heat pump at 1.5 m³/h
External available pressure differential, circulation pump / heat pump at 2.0 m³/h
External available pressure differential, circulation pump / heating circuit 1 at 1.0 m³/h
External available pressure differential, circulation pump / heating circuit 1 at 1.5 m³/h
External available pressure differential, circulation pump / heating circuit 1 at 2.0 m³/h
External available pressure differential, circulation pump / heating circuit 2 (optional) at 1.0 m³/h
External available pressure differential, circulation pump / heating circuit 2 (optional) at 1.5 m³/h
External available pressure differential, circulation pump / heating circuit 2 (optional) at 2.0 m³/h
Application limits
Max. permissible pressure, DHW cylinder
Test pressure, DHW cylinder
Max. throughput
Max. permissible pressure, buffer cylinder
Test pressure, buffer cylinder
Max. permissible temperature
Max. permissible temperature, primary side
Heating water quality requirements
Water hardness
pH value (with aluminium compounds)
pH value (without aluminium compounds)
Conductivity (softening)
Conductivity (desalinating)
Chloride
Oxygen 8-12 weeks after filling (softening)
Oxygen 8-12 weeks after filling (desalinating)
Power consumption
Power consumption, emergency/booster heater
Max. power consumption, charging pump
Max. power consumption, circulation pump, heating side
Energy data
Standby energy consumption/24 h at 65 °C
Energy efficiency class
Electrical details
Rated control voltage
Control phases
Control circuit fuse
Rated voltage, emergency/booster heater
Phases, emergency/booster heater
Emergency/booster heater fuse
Frequency
Versions
IP-Rating
58
| HSBC
HSBC 200
STIEBEL ELTRON
HSBC 200
W
l
HSBC 200 S
233510
STIEBEL ELTRON
B
55
189
HSBC 200
HSBC 200 S
233510
l
168
l
100
3.3
l
21
hPa
656
hPa
527
hPa
210
hPa
725
hPa
663
hPa
444
hPa
665
hPa
518
hPa
189
MPa
1.0
MPa
1.5
l/min
25
MPa
0.3
MPa
0.45
°C
95
°C
75
°dH
≤3
8.0-8.5
8.0-10.0
μS/cm
<1000
μS/cm
20-100
mg/l
<30
mg/l
<0.02
mg/l
<0.1
kW
8.8
W
60
W
60
kWh
1.3
B
V
230
1/N/PE
A
1 x B 16
V
400
3/N/PE
A
3 x B 16
Hz
50
IP20
www.stiebel-eltron.com
234801
HSBC 200 S
B
55
189
234801
168
100
3.3
21
656
527
210
725
663
444
665
518
189
1.0
1.5
25
0.3
0.45
95
75
≤3
8.0-8.5
8.0-10.0
<1000
20-100
<30
<0.02
<0.1
5.9
60
60
1.3
B
230
1/N/PE
1 x B 16
230
2/N/PE
2 x B 16
50
IP20

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hsbc 200 s