Field Setting from Outdoor Unit
No.
Item
1
Te setting (Heat
Used to make setting of targeted
recovery
evaporating temperature for heat
operation)
recovery operation.
47
Outdoor > 50 m
Height difference setting max. 110
49
(164 ft) above
m (361 ft).
indoor
Sequence multi
Sequence addressing between
51
outdoor
master and sub units.
Gas furnace
Used for gas furnace connection
60
setting
Cooling/Heating
Adjust cooling and heating capacity
capacity learning
learning control
62
control
Eco mode
Used to make setting of Eco mode
invalid setting
invalid
When this configuration is set, it is
64
not possible to turn Eco mode
ON/OFF using external control
adaptor or other setting.
Branch selector
Used for changing branch selector
switching time
switching time
71
All piping length between branch
selector unit and indoor units
should be less than 9.7 m (32 ft).
Heat pump
Heat pump is locked out when the
lockout
outdoor air temperature is smaller
temperature
than the heat pump lockout
temperature.
78
Heat pump
Heat pump would be resumed
lockout release
when the outdoor air temperature
79
differential
is recovered by differential above
the heat pump lockout
temperature.
Cooling comfort
Cooling comfort setting
setting
81
Heating comfort
Heating comfort setting
setting
82
Indoor unit
Multi-tenant function setting
without power
90
229
Description
SEG
1
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
7 segment
display
Description
SEG
SEG
2
3
Auto
6°C (42.8°F)
7°C (44.6°F)
4
7
8°C (46.4°F)
9°C (48.2°F)
10°C (50.0°F)
11°C (51.8°F)
Off (max. 50 m (164 ft))
4
9
On (max 110 m (361 ft))
Automatic
5
1
Forced master
Forced sub
No gas furnace connection
6
0
Gas furnace connection
OFF
Cooling adjustment
6
2
Heating adjustment
Cooling and heating
adjustment
Eco mode active
Te fix control
Tc fix control
6
4
Te & Tc fix control
Standard
Approximately 4 minutes
7
1
–26.1°C (–15°F)
–23.3°C (–10°F)
–20.5°C (–5°F)
–17.7°C (0°F)
–15°C (5°F)
–12.2°C (10°F)
–9.4°C (15°F)
7
8
–6.6°C (20°F)
–3.8°C (25°F)
–1.1°C (30°F)
1.6°C (35°F)
4.4°C (40°F)
7.2°C (45°F)
10°C (50°F)
Forced heat pump lockout
2.8°C (5°F)
5.6°C (10°F)
7
9
8.3°C (15°F)
Eco
Mild
8
1
Quick
Powerful
Eco
Mild
8
2
Quick
Powerful
Invalid
Valid (No U4 error generation)
9
0
Valid (Operating with U4
warning)
Part 5 Field Settings and Test Operation
SiUS372201EA
7 segment
display
Range
SEG
SEG
SEG
1
2
3
0
2
3
4
5
6
7
0
1
0
1
2
0
1
0
1
2
3
0
1
2
3
0
1
0
1
2
3
4
5
6
7
8
9
1
0
1
1
1
2
1
3
1
4
0
1
2
0
1
2
3
0
1
2
3
0
1
2