Instructions
VI.JA.C3.5B
PCVD, PCVSAD
9.4 Replacement of Trim Valve AVD, SAVD
AVD DN 25
Dismounting
1. Unscrew actuator (see above).
2. Unscrew trim 2.
DN 25: with pipe tongs, wrap gum strips
around the trim
DN 40: with wrench SW 55
3. Pull out trim.
2
2
Mounting
Mounting is carried out in reverse order. Only
tighten with low torque, sealing is made with
O rings.
AVD DN 40
© Danfoss | 2016.05 | 15