72
C
6: T
HAPTER
EC HN ICA L
R
EFERENC E
&F2 Software flow control template
&Gn Sets Guard Tone.
&G0
No guard tone, U.S. and Canada
&G1 550
Hz guard tone, some European countries, requires B0
setting.
&G2 1800 Hz guard tone, U.K., requires B0 setting.
&Hn Sets Transmit Data (TD) flow control (see also &Rn).
&H0 Flow control disabled
&H1 Hardware flow control, Clear to Send (CTS)
&H2 Software flow control, XON/XOFF
&H3 Hardware and software flow control
&In
Sets Receive Data (RD) software flow control (see also &Rn).
&I0
Software flow control disabled
&I1
XON/XOFFsignals to your modem and remote system
&I2
XON/XOFFsignals to your modem only
&Kn Enables/disables data compression.
&K0 Data compression disabled
&K1 Auto enable/disable
&K2 Data compression enabled
&K3 MNP5 compression disabled
&Mn Sets Error Control (ARQ) for connections at 1200 bps and
higher.
&M0 Normal mode, error control disabled
&M1 Reserved