SMC Networks ISE70G-N02-L2 Operation Manual page 68

High-precision digital pressure switch
Table of Contents

Advertisement

●Product individual parameters
Index
Access
Sub
∗1
dec
hex
index
Unit
1000 0x03E8
0
R/W
(Selection of display unit)
NorP
1001 0x03E9
0
R/W
(Selection of switch output
PNP/NPN)
CoL
1002 0x03EA
0
R/W
(Selection of display colour)
diAG
1003 0x03EB
0
R/W
(Selection of diagnostic
information)
1010 0x03F2
0
R/W
1011 0x03F3
0
R/W
1012 0x03F4
0
R/W
1013 0x03F5
0
R/W
1014 0x03F6
0
R/W
1015 0x03F7
0
R/W
1016 0x03F8
0
R/W
1017 0x03F9
0
R/W
1018 0x03FA
0
R/W
Data
Initial
Parameter
∗2
type
value
U8
0
U8
1
U8
2
U8
1
oUt1
U8
0
(Selecting output mode)
1ot
U8
0
(Selection of output type)
P_1(n_1)
U16
3000
(Selection of output
set value)
H_1
U16
1200
(Setting of OUT1
hysteresis)
P1L(n1L)
U16
2200
(Lower limit of window
comparator)
P1H(n1H)
U16
3400
(Upper limit of window
comparator)
WH1
U16
1400
(Upper limit of window
comparator)
dtH1
U16
0
(Delay time at ON)
dtL1
U16
0
(Delay time at OFF)
-67-
Data
Set value
∗3
storage
0: MPa
1: kPa
Y
2: kgf/cm
2
3: bar
4: Psi
0: nPn
Y
1: PnP
0: rEd (Constantly red)
1: Grn (Constantly green)
2: 1SoG
(OUT1 turns green at ON)
3: 1Sor
Y
(OUT1 turns red at ON)
4: 2SoG
(OUT2 turns green at ON)
5: 2Sor
(OUT2 turns green at ON)
0: Unused
Y
1: All errors
2: Pressurizing error
0: HYS (Hysteresis)
1: Wind
Y
(Window comparator)
2: Err (Error output)
3: oFF
0: 1_P (Normal output)
Y
1: 1_n (Reverse output)
Setting range
ISE70: 0x0244 ~ 0x1450
Y
(580 ~ 5200)
ISE71: 0x02E2 ~ 0x1450
(738 ~ 5200)
Setting range
ISE70: 0x03E8 ~ 0x15F4
Y
(1000 ~ 5620)
ISE71: 0x03E8 ~ 0x1556
(1000 ~ 5462)
Setting range
ISE70: 0x0244 ~ 0x1450
Y
(580 ~ 5200)
ISE71: 0x02E2 ~ 0x1450
(738 ~ 5200)
Setting range
ISE70: 0x0244 ~ 0x1450
Y
(580 ~ 5200)
ISE71: 0x02E2 ~ 0x1450
(738 ~ 5200)
Setting range
ISE70: 0x03E8 ~ 0x0CEE
Y
(1000 ~ 3310)
ISE71: 0x03E8 ~ 0x0C9F
(1000 ~ 3231)
Y
Settable values
0x0000 ~ 0x1770
(0 ~ 6000)
Y
Remarks
Setting of display unit
Setting of switch output specification
Setting of display colour
Sets the diagnostic information bit of
the input process data.
When "1: All errors" is selected and
the following error occurs, the
parameter turns ON.
Product internal failure
OUT2 over current error
Exceeding upper limit of the
temperature in the product
Exceeding upper limit of the
measurement pressure range
Less than the lower limit of the
measurement pressure range
When "Pressurizing error" is selected
and the following errors occur, the
parameter turns ON.
Exceeding upper limit of the
measurement pressure range
Less than the lower limit of the
measurement pressure range
Setting of OUT1 output mode
Setting of OUT1 output normal and
reserved output.
Setting of OUT1 output set value
Setting of OUT1 hysteresis
Setting of OUT1 output set value
(lower limit of window comparator)
Setting of OUT1 output set value
(upper limit of window comparator)
Setting of OUT1 hysteresis (window
comparator hysteresis)
Setting of OUT1 delay time at ON
0.01 s increment
Setting of OUT1 delay time at OFF
0.01 s increment
No.PS※※-OMV0004-H

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ise71 l2 seriesIse70 l2 seriesIse70-n02-l2

Table of Contents