∗: Measurement mode can return from any setting item by pressing the SET button for 2 seconds or longer.
OUT2 output check
Press the UP or DOWN button to select OUT2
output check.
Press the SET button to set.
Diagnostic output check
Press the UP or DOWN button to select the
diagnostic output check.
∗: IO-Link mode can provide the communication function.
∗: Refer to page
61
for details of the diagnostic information.
Press the SET button to set.
PD measurement value
The upper and lower limit values of the rated
pressure value can be output compulsively as
PD measurement value (process data). Press
the UP or DOWN button to select the lower or
upper limit value.
∗: IO-Link mode can provide the communication function.
∗: Refer to page
62
for details of the PD measurement value.
Press the SET button to
return to [n] (Normal output),
then press the SET button to set.
Return to function selection
mode.
[F98] Output check completed
-53-
No.PS※※-OMV0004-H