15.2 Connecting the control medium
1. Use suitable connectors.
2. Connect the control medium lines tension-free and
without any bends or knots.
Thread size of the control medium connector:
GEMÜ 650
diaphragm size 10, 40: G1/4
GEMÜ 687
diaphragm size 25, 40, 50: G1/4
Control function
1
Normally closed (NC)
For connector 2, see figures
15.3 Optical position indicator
Valve open
15.4 Stroke limiter
NOTICE
▶ For GEMÜ 687, there must not be a stroke limiter fitted.
www.gemu-group.com
Connector 2
Control medium (open)
Valve closed
43 / 52
16 Commissioning
Corrosive chemicals!
▶ Risk of caustic burns
Wear appropriate protective gear.
●
Completely drain the plant.
●
Leakage
▶ Emission of dangerous materials.
Provide precautionary measures against exceeding the
●
maximum permitted pressures caused by pressure
surges (water hammer).
Cleaning agent
▶ Damage to the GEMÜ product.
The plant operator is responsible for selecting the clean-
●
ing material and performing the procedure.
1. Check the tightness and the function of the product (close
and reopen the product).
2. Flush the piping system of new plant and following repair
work (the product must be fully open).
ð Harmful foreign matter has been removed.
ð The product is ready for use.
3. Commission the product.
4. Commissioning of actuators in accordance with the en-
closed instructions.
17 Operation
Operate the product according to the control function (see
also chapter "Pneumatic connections").