Part 7 - Data Communications; Setting Up For Data Communications; Performing Data Communications Between On Sf Unit And @ Personal Computer; To Connect The Sf Unit With A Personal Compute - Casio SF-4400 Owner's Manual

Hide thumbs Also See for SF-4400:
Table of Contents

Advertisement

PART 6
Poker Game
76
»
When both hands contain straights, the hand whose straight ends with the
highest card wins. When both hands end with the same card, the hand is a
tie:
A-K-Q-J-10 is the highest straight.
5.
A is the fowest straight.
Q-K-A-2-3 is not a straight.
«
When both hands contain three of a kind, the hand with the higher three of
a@ kind wins,
*
When
both hands contain two pairs, the hand with the highest pair wins.
When both hands have the same highest pair, the hand is decided by the
rank of the other pair. When both hands have the same two pair, the hand
is decided by the highest of the one unmatched card.
»
When both hands contain one pair, the hand with the high pair wins. When
both hands have the same pair, the hand is decided by the highest of the three
unmatched cards, and if necessary by the next highest unmatched card, and
so on.
«
When both hands are made up of five unmatched cards, the hand with the
highest card wins. When the high cards in both hands are the same, the b..;.d
is decided by the next highest card, and if necessary by the next highest card,
and so on.
Data Communications
Data communications capabilities tet you transfer data between two CASIO SF
Units, or between the SF Unit and a persona! computer. You can perform such
operations in the Telephone Directory, Memo, Schedule Keeper, Calendar, or
Reminder mode.
Setting Up for Data Communic:
ions
:
The following describes what you should do to set up for data communications
between two SF Units or between the SF-4400/SF-4600B and a personal
computer.
To connect the SF-4400/SF-4600B to another SF Unit
1. Make sure that the power of both units is switched off.
2. Remove the covers from the data communications jacks on the two SF Units.
3. Connect the two units using the SB-62 cable.
Important!
»
Youcannot perform data communications with the CASIO SF-A Series of SF
Units (SF-A10, etc.).
'
+
Be Sure to replace the connector covers on the SF Units when you are not
performing data communications.
¢
i
gayem
PART 7 Data Communications
Setting Up for Data Communications BAS,
Performing data communications between on SF Unit and a
3. Press 3 to select SET UP PAR.
personal computer
Note that the optionally available FA-120 V3.50d Interface Unit is for data
communications between the SF-4400/SF-4600B and a personal computer.
Though the FA-100 and FA-150 Interface Units can also be used for data
communications, the software that comes with these interface units is unable to
78
transfer Reminder data.
To connect the SF Unit with a personal computer
1
First, ensure that the power of the SF Unit and the personal computer is
.
.
The highlighted items on the display are the parameters that are currently
set.
The PARITY parameter is flashing because it is selected.
he
switched OFF.
4
aia, A and Veursor keys to change the selected parameter on the
2. Connect the personal computer to the FA-120 interface Unit.
2
ighli
hi
he highlighted setting
of the
3. Remove the connector cover from the connector terminal of the SF Unit.
2
oe
Stier
fo;ehange the-highigs
#
+
Be careful not to jose the connector cover. It should be replaced in the
6.
When he parameters are set the way you want them, press SET to store
connector terminal whenever the cable is disconnected.
Connect the SF Unit to the FA-120 interlace Unit.
Switch the power of the personal computer ON, followed by the SF Unit.
When
data transfer operations are complete, switch power off in the se-
quence; SF Unit and then personal computer.
Next, disconnect the units.
The above operation is based on the FA-120 V3.50d interface Unit. For
Information on using the FA-100 or FA-150, consult the Owner's Manuals
that come with these interface units.
For details on computer hardware requirements, see the communica-
tions software manual,
To set the SF Unit hardware parameters
1.
2.
Press FUNC twice to display the second function menu.
You can perform the above operation in the Telephone Directory, Memo
Mode, Schedule Keeper, Calendar or Reminder.
Press 4 to select DATA COMM.
them in memory.
About communications parameters...
Communications parameters make it possible for two communicating units
to understand each other, The following explanations are provided for your
information only. The only thing you need to remember is that the param-
eters of the send unit and the receive unit must be identical. Otherwise you
will not be able to transfer data successfully.
Parity
Parity is used for error detection during data exchanges. You can set the
SF Unit parity as even (E}, odd (0), or none {N}.
Bit Length
>
The bit length parameter states how many bits are to be used for each
character. You can set the SF Unit bit length as 7 bits or 8 bits.-
BPS
The fetters "BPS" stand for "bits per second," and this setting represents
the speed at which data is sent. The SF Unit lets you set a speed of either
4800 or 9600.
79

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sf-4600b

Table of Contents