2. Installation

The backup battery option must be specified at the time of order. You can't
upgrade the instrument with this option without sending it back to factory.
2
Installation
Indu Altimeter requires a standard size 57/80 mm hole in the instrument
panel. The position of the hole must ensure good access to the instrument for
the QNH adjustments and it must be always visible from the pilot's perspec-
tive.
2.1
Mounting & Dimensions
The mounting screw holes are located on a circle of 66.5/89 mm diameter.
The instrument is mounted using three screws type M4. To prevent internal
stresses, please make sure that the instrument panel is flat.
Remove the mounting screws from the instrument and then remove the knob.
Use finger nail or sharp knife to remove the cap from the knob, but be careful
not to cut the cup away. Once the cap is removed, use flat screwdriver and
loosen the screw. Slide the knob from its axle. Figure 2 shows an example of
the knob with its cap removed.
Figure 2: Photo of the knob with its cap removed.
It is highly recommended that the instrument panel is mounted using rubber
shocks, which reduce the vibrations. Figure 3 illustrates the mounting hole.