  • Page 1 INDU COMBO Manual Kanardia d.o.o. November 2018 Revision 1.0...
  • Page 3 In short, the license gives you right to copy, reproduce and modify this document ˆ you cite Kanardia d.o.o. as the author of the original work, ˆ you distribute the resulting work only under the same or similar license to this one.
  • Page 4 QCad applications. Photos and scanned material was processed using Gimp. All document sources are freely available on request under the licence mentioned above and can be obtained by email. Please send requests to info@kanardia.eu. Revision History The following table shows the revision history of this document.
  • Page 5: Table Of Contents

    3.3 Toggle Illumination Knob ....4 Maintenance & Repair 5 Troubleshooting 5.1 Freeze During Engine Start ....© Kanardia 2015-2018...
  • Page 6 7.1 Warranty ......7.2 TSO Information ....© Kanardia 2015-2018...
  • Page 7: Introduction

    Introduction First of all, we would like to thank you for purchasing our device. Indu Combo is an electronic device, which mimics classical construc- tion and combines it with the state of the art electronics. This results in the best of both worlds; a perfect and intuitive analogue reading combined with high precision of modern electronics.
  • Page 8: Technical Specification

    31.89 inHg) Internal logger storage more than 50 h, 1 s interval Communication CAN bus, 29 bit header, 500 kbit, Kanardia protocol Table 1: Basic technical specifications. Options 1.3.1 Scale The instrument can be delivered with different scales. Basically, there are no standard scales and you have to define the scale units and scale...
  • Page 9 Scale is then custom made for each individual order. Scale holds color-coded markings in order to give the pilot immediate reference. The following markings are possible: ˆ V – Red line on the top of yellow arc. This designates © Kanardia 2015-2018...
  • Page 10: Display

    QNH settings in the middle and vertical speed at the bottom. Figure 3 shows the display. If you want a different LCD display layout, you can configure it your- self with our Customizer desktop application. This option requires Available from April 2020 © Kanardia 2015-2018...
  • Page 11 Figure 2: A scale example with the markings. 2000 1014 Figure 3: Combo display example. Kanardia’s Blu device for transfering the configuration from your android device to your Indu Combo. Please read our Customizer Manual for more information. © Kanardia 2015-2018...
  • Page 12: Installation

    It is highly recommended that the instrument panel is mounted using rubber shocks, which reduce the vibrations. Figure 5 illustrates the mounting hole for both sizes of instrument. Bottom left hole is used for the push button strut. © Kanardia 2015-2018...
  • Page 13 Combo — Manual 2.1 Mounting & Dimensions (a) 57 mm (b) 80 mm Figure 5: Instrument panel cutout and mounting hole. Note: Figure is not in scale. © Kanardia 2015-2018...
  • Page 14: Connections

    Figure 6: Back view of the instrument with connections. 2.2.1 Static Pressure - Pst Indu Combo must be connected to the static pressure source. Static pressure source is usually obtained from pressure sources located on the fuselage side surfaces or from the static port on the pitot tube.
  • Page 15: Total Pressure - Ptot

    Water must not be allowed to enter the tubing. It is strongly recommended to label each tube before connecting to Indu Combo. This will help a lot if you ever have to remove and re-install the instrument.
  • Page 16: Power - Power

    1013 for hPa or 30.12 29.50 29.91 for inHg. A minor sensor offset may be required in order to adjust Indu Combo according to some other reference instrument. Please, follow the steps given below in order to make the adjustment. A precise reference instrument is needed in this procedure.
  • Page 17: Toggle Qnh Hpa - Inhg

    Combo — Manual 3.2 Toggle QNH hPa – inHg 2. Turn the knob on Indu Combo to indicate 1020 hPa (30.12 inHg) and wait for about 3 seconds for a short cyan line to appear on the top of LCD display.
  • Page 18: Toggle Illumination Knob

    3. Turn the knob to 1013 hPa (29.91 inHg) to complete the pro- cedure. 4. Finally, you need to turn off Indu Combo and then back on in order to activate the change. Maintenance & Repair No special maintenance is required.
  • Page 19: Troubleshooting

    1000 F, at least 25 V and at least 100 C working temperature. Diode 1N5818G +12 V Instrument Capacitor 1000 μF, 25V, 108°C Figure 7: Circuit that may prevent sudden voltage drops in certain installations. © Kanardia 2015-2018...
  • Page 20: Sensor Calibration

    11000 meters of geopotential altitude. The thropopause layer is modeled by equation (2) up to 20000 meters of geopotential altitude. As the pressure sensor is calibrated down to 100 hPa (about 16000 meters) altitudes above 16000 meters are not reliable. © Kanardia 2015-2018...
  • Page 21: Altitude Derivative

    Although a great care was taken during the design, production, stor- age and handling, it may happen that the Product will be defective in some way. Please read the following sections about the warranty and the limited operation to get more information about the subject. © Kanardia 2015-2018...
  • Page 22: Warranty

    Exclusions and Limitations This Limited Warranty applies only to hardware products manufac- tured by or for Kanardia that have the ”Kanardia” trademark, trade name, or logo affixed to them at the time of manufacture by Ka- nardia. The Limited Warranty does not apply to any non-Kanardia ©...
  • Page 23 Kanardia; (f) to consumable parts, such as batteries, unless damage has occurred due to a defect in materials or workmanship; or (g) if any Kanardia serial number has been removed, altered or defaced.
  • Page 24: 7.2 Tso Information

    Kanardia products and any failure to maintain the confidentiality of data stored on the product. Under no circumstances will Kanardia be liable for the provision of substitute goods or services.
  • Page 25 Combo — Manual 7.2 TSO Information by its use. The Kanardia is not responsible for any possible damage or destruction of any part on the airplane caused by default operation of instrument. © Kanardia 2015-2018...

Table of Contents