QCad applications. Photos and scanned material was processed using Gimp. All document sources are freely available on request under the licence mentioned above and can be obtained by email. Please send requests to info@kanardia.eu. Revision History The following table shows the revision history of this document.
Introduction First of all, we would like to thank you for purchasing our device. Indu Combo is an electronic device, which mimics classical construc- tion and combines it with the state of the art electronics. This results in the best of both worlds; a perfect and intuitive analogue reading combined with high precision of modern electronics.
31.89 inHg) Internal logger storage more than 50 h, 1 s interval Communication CAN bus, 29 bit header, 500 kbit, Kanardia protocol Table 1: Basic technical specifications. Options 1.3.1 Scale The instrument can be delivered with different scales. Basically, there are no standard scales and you have to define the scale units and scale...
Figure 6: Back view of the instrument with connections. 2.2.1 Static Pressure - Pst Indu Combo must be connected to the static pressure source. Static pressure source is usually obtained from pressure sources located on the fuselage side surfaces or from the static port on the pitot tube.
Water must not be allowed to enter the tubing. It is strongly recommended to label each tube before connecting to Indu Combo. This will help a lot if you ever have to remove and re-install the instrument.
1013 for hPa or 30.12 29.50 29.91 for inHg. A minor sensor offset may be required in order to adjust Indu Combo according to some other reference instrument. Please, follow the steps given below in order to make the adjustment. A precise reference instrument is needed in this procedure.
Combo — Manual 3.2 Toggle QNH hPa – inHg 2. Turn the knob on Indu Combo to indicate 1020 hPa (30.12 inHg) and wait for about 3 seconds for a short cyan line to appear on the top of LCD display.
3. Turn the knob to 1013 hPa (29.91 inHg) to complete the pro- cedure. 4. Finally, you need to turn off Indu Combo and then back on in order to activate the change. Maintenance & Repair No special maintenance is required.
Page 23
Kanardia; (f) to consumable parts, such as batteries, unless damage has occurred due to a defect in materials or workmanship; or (g) if any Kanardia serial number has been removed, altered or defaced.
Kanardia products and any failure to maintain the confidentiality of data stored on the product. Under no circumstances will Kanardia be liable for the provision of substitute goods or services.