Class
Function
Judgment Output
Selection
Threshold a Sets threshold a
Displace
ment
Threshold b
Judgment
Hysteresis Sets the hysteresis.
Judgment Output OFF
Delay
Measurement Value
Display on Panel
Analog Output
Selection
Meas A
Meas B
Current a
Analog
Scaling
Current b
Voltage a
Voltage b
Analog Output at Alarm
Digital Output at Alarm
Alarm Delay Times
Terminating Resistor
Selection
Sensor no.
Baud rate
Connection Mode
Sending Delay Time
Timing Mode
Laser Control
Eco Mode
View Version
Initialization
Save
Timing
Ramco Innovations (800) 280-6933 www.panasonicsensors.com nsales@ramcoi.com
Details
Sets the operation of the output block.
and threshold b.
Delays the timing of judgment output switched OFF
from ON.
Turns OFF the rightmost digits on the digital display.
Selects the desired output type from current output and
voltage output.
Default: Negative measurement range
Performs scaling
Default: Positive measurement range
the analog current
output and the
analog voltage
output to any
desired value.
Sets the analog output status at alarm operation.
Sets the digital output status at alarm operation.
Holds the previous normal value up to the setting
number of times if an alarm is issued.
Selects the terminating resistor for the sensor head
connecting to the host device over RS-422/485.
Sets the number of each sensor head multi connected
to an RS-485 device.
Sets the communication speed.
Selects the performance settings for measurement data
output to the host device.
Set the sensor's delay time in response to each
command transmitted from the host device.
Sets the timing input mode.
Switches laser emission/stop.
Turns OFF the LED indicators on the control panel for
energy saving while the system is in RUN mode.
Displays the program version of the sensor.
Initializes the memory settings currently in use.
Saves all memory settings.
Holds the measurement value.
Initial value
Default: 2-state
Default: +(detection range)
Default: -(detection range)
Default: +(0.2% of setting range)
Default: OFF
Default: SET 1
Default: Current output
Default: +4.000 mA
Default: +20.000 mA
Default: 0.000 V
Default: 10.000 V
Default: Holds previous value
Default: Holds previous value
Default: 8 times
Default: R3
Default: 01
Default: 38400 bps
Default: RS-485 Multiple
Default: 0ms
Default: Hold
Default: Emission
Default: Eco OFF
Default: OFF
Memory
Ref.
change*
page
3-23
3-25
3-27
3-29
3-30
3-31
3-33
3-34
3-35
3-36
3-37
3-38
3-39
3-40
3-41
3-42
3-43
-
3-44
3-45
3-46
-
3-47