Repair Token Cable
1. Follow the Prepare the Motor for Repair procedure
on page 8.
2. Remove the electronics cover. See Replace
Electronics Cover on page 12.
3. Remove the twelve screws (20) and washers from
electronics cover (50).
4. Carefully tilt the electronics cover (50) down.
All wires must be disconnected before the cover is
completely removed. Hold the cover in place while
disconnecting the wires or let the cover rest on a work
surface to avoid damaging the wires and connections.
5. Check the token wire (TW) connections. Replace the
wire if it is damaged.
NOTE: Make sure the token wire connection is
positioned with the wires facing the bottom of the
sprayer.
3A7940A
NOTICE
TW
6. Install the cover (50) and tighten the twelve screws
(20) and washers. Torque to 15-20 ft-lb (20-27 N•m).
Make sure all wires are positioned inside the cover
before installation. If wires get pinched when the cover
screws are tightened, damage will occur.
7. Connect the power cord (Z).
50
NOTICE
Repair
20
17