8. Install the new fan assembly (FA). To reattach the fan
assembly, slide it into the slots for tabs located on the
junction box side and gently push down the far end of
the assembly. Apply thread locker and use the
supplied fasteners (FS) and washers to secure the
assembly into place. Torque to 15 - 20 ft-lb (20 - 27
N•m).
FS
9. Route the wires through the fan cord grip (C1)
attached to the motor (A), not the junction box (S).
10. Reattach the ground wire to the grounding screw
(GS). Tighten the ground screw.
3A7940A
FA
S
C1
GS
11. Use a ferrule to connect each fan wire to one of the
two wires coming out of the motor grommet. Then
attach one wire set into the disconnect box location
1L1 and the other wire into location 3L2.
12. Gently tuck the wires back into junction box around
the disconnect block (DB), then reinstall the junction
box cover (5). Replace the two screws (6) and
washers (7), then tighten.
5
6
7
Make sure all wires are positioned inside the cover
before installation. If the wires get pinched when the
cover screws are tightened, damage will occur.
13. Tighten the fan cord grip (C1) attached directly to the
motor.
DB
NOTICE
C1
Repair
GS
11