Panasonic CS-NZ35YKE Service Manual page 131

Hide thumbs Also See for CS-NZ35YKE:
Table of Contents

Advertisement

17.4.24 F95 (Outdoor High Pressure Protection: Cooling or Soft Dry)
Malfunction Decision Conditions
During operation of cooling or soft dry, when outdoor unit heat exchanger high temperature data is detected by
the outdoor unit heat exchanger thermistor.
Malfunction Caused
Outdoor heat exchanger temperature rise due to short-circuit of hot discharge air flow.
Outdoor heat exchanger temperature rise due to defective of outdoor fan motor.
Outdoor heat exchange temperature rise due to defective outdoor heat exchanger thermistor.
Outdoor heat exchanger temperature rise due to defective of outdoor unit PCB.
Troubleshooting
131

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-nz25ykeCs-nz50ykeCu-nz25ykeCu-nz35ykeCu-nz50yke

Table of Contents