Panasonic CS-NZ35YKE Service Manual page 28

Hide thumbs Also See for CS-NZ35YKE:
Table of Contents

Advertisement

9.2.2
CU-NZ50YKE
FOR OUTDOOR POWER
SUPPLY CONNECTION
SINGLE PHASE
T
O INDOOR UNIT
POWER SUPPLY
L
N
1
2
BLU
BLK
BRW
FOR INDOOR POWER
SUPPLY CONNECTION
POWER SUPPLY
NOT CONNECTED
L
N
BRW
SOUND PROOF
BOARD
BASE PAN
HEATER
Resistance of Compressor Windings
MODEL
CONNECTION
U-V
U-W
V-W
Note: Resistance at 20°C of ambient temperature.
TERMINAL
3
BOARD
DATA
(BLK)
FUSE 1
AC-BRW
(25A 250V)
(BRW)
AC-BLU
(BLU)
GRN
FG1
(GRN)
GRN
FG2
(GRN)
BLU
HT2 (BLU)
RY-HT2
BLU
ACN2 (BLU)
ELECTRONIC CONTROLLER (MAIN)
CU-NZ50YKE
9RD132XGA21
1.708 Ω
1.708 Ω
1.708 Ω
REACTOR
GRY
GRY
RAT2
RAT1
(GRY)
(GRY)
FUSE 4
FUSE 5
(20A 250V)
(20A 250V)
FUSE 3
T3.15A L250V
FUSE 2
T3.15A L250V
IC19
28
1
2
11
28
OUTDOOR AIR TEMP. SENSOR
(THERMISTOR)
CN-TH1
(WHT)
PIPING TEMP. SENSOR
(THERMISTOR)
CN-TANK
(WHT)
COMPRESSOR TEMP. SENSOR
(THERMISTOR)
ELECTRO-MAGNETIC
CN-HOT
COIL (4-WAY VALVE)
(WHT)
ELECTRO-MAGNETIC
CN-STM1
COIL (EXPANSION VALVE)
(WHT)
U (RED)
RED
BLU
V (BLU)
W (YLW)
YLW
COMPRESSOR
CN-MTR2
(WHT)
FAN MOTOR

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-nz25ykeCs-nz50ykeCu-nz25ykeCu-nz35ykeCu-nz50yke

Table of Contents