To exclude a "User" card from the Local List, the procedure is the same as for inclusion—just repeat the
previous steps. If the card is already registered in the Local List, it will be deleted. If the exclusion is
successful, the station will emit 2 (two) short beeps, and the RFID reader LED will change to solid green.
(1) solid green LED
(2) flashing green LED
NOTE!
The charging station allows the registration of up to 100 (one hundred) "User" RFID cards;
The station will emit a long beep when an unregistered card approaches the RFID reader.

6.6 FACTORY RESET

If you need to perform a factory reset, change the commissioning settings or delete the Local List of RFID
cards (it must be done with the front door open, and the station powered). Find the "SW2 - RESET" button
in the central part of the electronic board and keep it pressed for:
Three seconds (3 s) to delete all commissioning settings and the RFID "Master" card. After this
period, the station will emit 1 (one) short beep. Release the button and wait for the station to restart;
Five seconds (5 s) to delete all commissioning settings and Local List of cards ("User" and
"Master"). After this period, the station will emit 2 (two) short beeps. Release the button and wait
for the station to restart.
1x beep
Figure 27: Registration/Exclusion of the "User" RFID card
1x beep "User" Registration
2x beep "User" Exclusion