Environmental conditions for operation:
Temperature: -25 °C to 40 °C - rated conditions. From 41 ºC to 50 ºC - with derating;
Air relative humidity: 5% to 95% non-condensing;
Install the station in environments with air circulation;
Maximum altitude: 2000 m above sea level - rated conditions. For applications at higher altitudes,
contact WEG;
Condensation must not cause conductivity in the pollution.

3.2.2 Cleaning and Maintenance

DANGER!
Before starting cleaning and/or servicing the charging station, make sure that the upstream
circuit breaker is turned off.
To ensure proper operating conditions and a longer service life of the station, the following requirements
must be observed:
Periodically clean the outside the station, cables and charging plugs. It is recommended at least
once a month;
Clean it with the station turned off;
Never perform the cleaning while the electric vehicle is being charged;
To perform the cleaning, use a soft, dry cloth only;
Do not use abrasive cloths, sponges and detergents;
Do not spill water or other liquids over the equipment;
Do not use alcohol, solvents or chemical products;
If the charging station is very dirty, use a cloth slightly dampened with water to remove dust and
accumulated dirt;
Always keep the air inlets clean and free of any material that may prevent air circulation;
Clean the air filters every 6 months;
Replace the air inlet and outlet filters every 12 months;
Optionally, apply automotive wax only to metal parts for extra protection.
The following points need to be checked regularly:
Condition of the protection and switching devices, especially regarding the wear caused by arc and
loosening of the contacts;
Installing and Connecting