Menu Tree Of Hpe Smart Array S100I Utility - NEC N8100-2834F Maintenance Manual

Express server
Table of Contents

Advertisement

Chapter 2 Useful Features
2.3

Menu Tree of HPE Smart Array S100i Utility

Menu
Controller Information
Controller
Device ID
PCI Slot number
Firmware version
Firmware release date
UEFI Driver version
UEFI Driver release date
Configuration Summary
Configure Controller Settings
> Modify Controller Settings
Rebuild Priority
Surface Scan Analysis Priority
Current Parallel Surface Scan Count
Spare Activation Mode
Physical Drive Write Cache State
> Advanced Controller Settings
Physical Drive Request Elevator Sort
Monitor and Performance Analysis Delay
HDD Flexible Latency Optimization
Default Value
HPE Smart
Array S100 SR
Gen10
High
3
1
Failure Spare
Activation
Disabled
Enabled
60
Disabled
Express5800/R120h-1M, R120h-2M (3rd-Gen) Maintenance Guide
2. RAID System Configuration
Descriptions
Controller Information
PCIe device ID
PCIe Slot number
Firmware version
Firmware release date
UEFI Driver version
UEFI Driver release date
Summary of disk and array information
Priority at which the logical drives are
rebuilt from the failed state. It can be low,
medium, medium high or high.
0:Disable. 31:High. 1-31:Idle(with delay).
Modifies the amount of delay/idle time of
the controller before the surface scan
analysis is resumed again.
Set the maximum number of surface scans
that can run at the same time. Setting 1
disables the feature.
Option to change between the failure or
predictive spare activation modes.
Option for enabling the write cache on the
physical drives.
Enable or disable the physical drive cache
write elevator sort algorithm.
0-1440: input range. 60: Default.
Set the monitor and performance analysis
delay.
Enable or Disable the flexible Latency
scheduler to limit the high latency request
from the HDDs.
81