3

Operating manual

Carefully read and observe the detailed safety instruc-
tions at the start of this manual.
NOTE
The device heats the water flowing through it.
3.1

Control panel

1
Operating status LED
2
Temperature preselection for the bathtub
3
Temperature preselection for washing dishes
4
Maximum temperature
5
Temperature selection dial
6
Minimum temperature
7
Temperature preselection for washing hands
8
Temperature preselection for showering
3.2

Before commissioning the device

NOTE
The initial commissioning of the device must be per-
formed by a qualified professional. All required infor-
mation for the proper operation of the device must be
made available to customers.
NOTE
Never operate the device without water supply. This
can damage the heating elements.
EN-6
3.3

Switching the device on/off

Switching on
Open the hot water tap.
The device is switched on. The water heats up as it
flows through the device.
Switching off
Close the hot water tap.
3.3.1 LED status display
LED
Off
White LED
The white LED
flashes
(once a second)
The white LED
flashes
(twice a second)
Red LED
The white LED
flashes 4 times
3.4

Setting the temperature

The setting range for the domestic hot water temper-
ature is 20 °C to 60 °C.
To select a hot water temperature within this range,
turn the temperature selection dial left or right.
To avoid wasting energy and prevent premature calci-
fication of the device, select the desired temperature
as precisely as possible on the device.
NOTE
The device makes it possible to regulate the potable
water temperature precisely and can therefore be
connected directly to the shower. If the device is
nevertheless operated with a thermostatic fitting, the
temperature recommended by the fitting's manufac-
turer must be set on the device. If there are no clear
specifications, we recommend setting a temperature
of 50 °C.
6721873500 (2023/07)
DEE 1521, DEE 2127
Device status
The device is switched off
The device is switched on
The device is not reaching the set
temperature. The device has reached
the performance limit (see
chapter 8.).
Ventilation mode is active, the device
switches on with a delay.
Malfunction of the device (see
chapter 8.)
The water inlet temperature is higher
than the temperature selected on the
device (solar). The device does not
heat up.