Help in case of faults

Repairs should only be carried out by suitably qualified staff.
Regular inspection and maintenance prevent faults from occurring
during operation and help to ensure safety. The inspection and
maintenance intervals depend on the way the appliance is used. Ask
the customer service staff of your dealer or send for the current
customer service information material provided by the manufacturer.
Problem
Emission of steam in lower area.
The appliance is switched on but does not heat
up.
Display "Appliance in use" lights up, heating
display is not illuminated.
Simmering proceeds at too high a temperature
in spite of temperature regulator being switched
on.
Appliance switched on but it does not heat up
or only very slowly.
The LED display "Appliance in use" and the
heating display come on.
Appliance cannot be switched on.
When the appliance is switched on, the
customer fuses repeatedly blow.
"F1" indicated in the display.
LED display "Fault" comes on.
"F2" indicated in the display.
LED display "Fault" comes on.
"F5" indicated in the display.
LED display "Fault" comes on, the appliance
switches off.
"F10" indicated in the display.
LED display "Fault" comes on.
"Pdr" indicated in the display.
FES/UES 07 25 13 Bl.27
Possible cause
Overpressure valve released.
a) Target temperature set too low.
b) Additional starting time preselection switched
on.
Target temperature set too high.
a) Customer fuse defective.
b) Heating element defective.
a) Customer fuse defective.
b) Mains connection interrupted
a) Incorrect fuses.
b) Appliance defective.
System fault.
Fault of the temperature sensor for the cooking
chamber.
a) Protection-against-boiling dry function has
been released. It is possible that the preassure
container is no longer full or needs topping up.
b) Safety cut-out after the pressure in the
steam generator has risen above the maximum
admissible value to 0.6 bar.
a) Two buttons pressed together for more than
10 sec.
b) Button jammed.
Normal display after disconnection of the
appliance from the mains.
Help in case of faults
Remedy
The appliance is defective. Call customer
service.
a) Adjust target temperature to the correct
setting.
b) Switch off timer.
Adjust target temperature to the correct setting.
a) Check fuse and replace if necessary.
b) Disconnect the appliance from the mains via
the fuse, inform customer service.
a) Check fuse and replace if necessary.
b) Have a technician check to see whether the
appliance is connected to the customer's
mains; if necessary, reconnect.
a) Have fuses checked by an
electrician.
b) Disconnect appliance from the mains and
call customer service.
Call customer service.
Call customer service.
If necessary, the appliance may continue to be
operated at the high power setting.
Disconnect the appliance from the mains and
call customer service.
a) Press buttons individually.
b) Release jammed button by activating it
several times. Otherwise, call customer service.
Acknowledge message by activating the On/Off
button.