Introduction Product Overview Product Description This product is a ceiling mount exhaust fan with a metal casing. This fan has rotating parts and personnel must exercise safety precautions during installation, operations, and maintenance. Intended Use Use this product only in the manner intended by Fantech. If you have any questions, please contact a Fantech representative.
• Never place a switch where it can be reached from a tub or Safety shower. • Do not use this product with any solid-state speed control Safety definitions device. Warnings, cautions and notes are used to point out specially •...
Using (2) A Screws, attach (1) rubber 3 to the back side of Installation (1) hanger bracket. To Set the Product Speed Using (2) A Screws, attach (1) hanger bracket to the side of the product casing. Through the top of (1) hanger bracket, connect (1) rubber 1 Note: to (1) rubber 2.
Examine the duct around the duct connector to make sure Caution the seal is air tight. To keep pressure losses to a minimum, and promote sufficient airflow, observe the following: • Where possible, use short and straight duct run lengths. •...
Electrical connection Motor Protection This product has integrated motor thermal overload protection. To do before the electrical Reset the motor protection by disconnecting the fan from power connection supply for 60 seconds. • Make sure that the electrical connection agrees with the product specification on the motor name plate.
COM200–300–400–500 ON/OFF SWITCH LINE SWITCH BOX UNIT COM200–300–400–500 BLACK (BLK) WHITE (WHT) GROUND (GRD) WIRE UNIT PANEL SWITCH RECEPTACLE SWITCH BOX POWER SUPPLY 120V AC To Attach the Ceiling Grille Make a cut around the casing of the product. Attach (2) grille springs into the correct holes of the ceiling grille.
Operation Maintenance To Start the Product Warning Set the installed switch(es) in the OFF Make sure that 120 volts of Alternate Current (AC) wiring position before you do the maintenance are attached to the product. unless the instructions tell you differently. Set the switch to the ON position.
Technical data Voltage, Motor Power, Frequency Refer to the mo- tor nameplate on Technical Data Overview the blower assembly. Motor data Refer to the mo- tor nameplate or the technical documentation from the motor manufacturer. Product Dimensions Note: Dimensions are given in inches (mm). bathfan Commercial 8 (203) 14–1/8 (359)