AIR CIRCULATION OF THE HEATING SYSTEM

Always refer to the applicable national building code before installing the hot air
conduct.
FLOOR GRILLE
FLOOR GRILLE
Hot air pipe:
An air supply must be installed if:
 The appliance seems to have an irregular draft control, a smoke return, a
bad combustion and a counterblow whether you have combustion or not.
 Your other appliances, such as hearths or other heating appliances,
release odors, provide poor performance, provoke smoke return or a
counterblow whether there is combustion or not.
 If the window is open, even slightly, in the calm weather (no wind), the
situation above is solved.
 Your home is built with vapour barrier and airtight windows, and/or with a
system device to blow the air outside.
In these circumstances, which mean the air infiltration is insufficient, you must
ensure an adequate air supply.
* In doubt, it is recommended to ensure an adequate supply of fresh air.
September 13, 2016
FLOOR GRILLE
FLOOR GRILLE
8" diameter for 20 feet length.
6" diameter for 15 feet length.
It is recommended to
install
floor
grilles
order to balance the air
pressure
between
floors
where
appliance is installed and
the upper floor.
It is also recommended
to
install
these
grilles
to
each
extremity.
in
the
the
floor
home
22