Permissible Load For The Output Shaft - Mitsubishi Electric MELSERVO-J5-HK-KT Series User Manual

Rotary servo motor
Table of Contents

Advertisement

Permissible load for the output shaft

The permissible load for the shaft is shown in the following. Do not subject the shaft to loads greater than the permissible
value. The value assumes that the load is applied independently.
Distance L from flange mounting
surface to load center
In case where the load position changes, calculate the permissible radial load from the distance measured from the flange
mounting surface to the center of the load, and make the load equal to or less than the permissible radial load, referring to the
graph shown in the following.
Model
Radial load
Load position L
[mm]
HK-KT053W
25
HK-KT13W
HK-KT1M3W
HK-KT13UW
HK-KT23W
30
HK-KT43(4)W
HK-KT63(4)W
HK-KT23UW
HK-KT43UW
6 HK-KT SERIES
118
6.2 Standard specifications
Radial load
Thrust load
Load [N]
88
245
Thrust load
The graph of the relation between the load and the load
position
Load [N]
59
125
120
115
110
105
100
95
90
85
80
0
98
340
320
300
280
260
240
220
0
5
10
15
Distance L from flange surface [mm]
5
10
15
20
Distance L from flange surface [mm]
20
25
25
30

Advertisement

Table of Contents
loading