MR-AEKCBL_M-L/MR-AEKCBL_M-H

Item
MR-AEKCBL_M-L
MR-AEKCBL_M-H
Item
MR-AEKCBL_M-L
MR-AEKCBL_M-H
Item
MR-AEKCBL_M-L
MR-AEKCBL_M-H
Item
MR-AEKCBL_M-L
MR-AEKCBL_M-H
HRZDEV-SLAB-C18448(20276)
Reference diagram
1
4
5
2
5 WIRING OPTION
98
5.4 Wires for option cables
Cable
length
[m]
For encoder
20, 30
For encoder
20 to 50
Physical characteristics
Conductor construction Braided shielding
For encoder
AWG 15 × 2 cores
AWG 22 × 2 pairs
AWG 24 × 1 pair
For encoder
AWG 15 × 2 cores
AWG 23 × 2 pairs
AWG 24 × 1 pair
Wire specifications
Conductor OD [mm]
For encoder
1.83 (AWG 15)
0.78 (AWG 22)
0.6 (AWG 24)
For encoder
2.0 (AWG 15)
0.72 (AWG 23)
0.61 (AWG 24)
Wire specifications
Rated
temperature
[°C]
For encoder
80
For encoder
80
AWG 15
1: Red
2: White
Shield braid
AWG 22
3: Green and blue
4: Gray and black
AWG 24
3
5: Purple and orange
Flex type
Applicable standard
For wiring between devices
UL 758 (AWM)
Standard (for fixed parts)
UL style 20276
High flex life (for moving
UL style 20276
parts)
material
Tinned annealed copper wire
Tinned annealed copper wire
Cable OD
Minimum bending
*1
radius [mm]
[mm]
(recommended
value)
8.6
4 times the cable OD
8.7
4 times the cable OD
Conductor
Rated voltage
resistance
[V]
(at 20 °C)
[Ω/km]
10.5 or less
30
55.5 or less
93.9 or less
11.0 or less
30
72.9 or less
99.4 or less
RMDCV-SLAB-C18451(20276)
Reference diagram
1
4
2
Sheath material
Flame-retardant and oil-
resistant PVC
Flame-retardant and oil-
resistant PVC
Insulation
resistance
(at 20 °C)
[MΩ/km]
100 or more
100 or more
Recommended product
Model
HRZDEV-SLAB-
C18448 (20276)
RMDCV-SLAB-
C18451 (20276)
AWG 15
1: Red
2: White
Shield braid
AWG 23
3: Green and blue
4: Gray and black
AWG 24
3
5: Purple and orange
5
Flame retardant
UL 1581
VW-1
VW-1
Color
Black
Black
Withstand
voltage
[Vac/min]
500
500
Manufacturer
Dyden

Advertisement

Table of Contents
loading