Analog Tests Screen - Honeywell BENDIX/KING KAP 140 Maintenance Manual

Flight control system
Hide thumbs Also See for BENDIX/KING KAP 140:
Table of Contents

Advertisement

3.3.10 ANALOG TESTS SCREEN

Pressing 'T' when the Diagnostics Menu screen is displayed will cause the Analog Tests screen,
shown in Figure 3--11, to be displayed. Pressing 'ENTER' when this screen is displayed returns
the user to the Diagnostics Menu screen. Pressing a key corresponding to a particular test on the
Analog Test screen will cause that test to be performed.
Test selections 1 through 3, 'Display All Segments', 'Display No Segments', and Display 'RUN
OUT FOR ALE' are designed to exercise the gas--discharge display. These tests allow the user
to check for missing segments, verify all segments turn off, and evaluate display brightness
settings.
Test selection 4 verifies the KCM 100 Configuration Module (Nonvolatile Memory) is working
properly. The FCC copies the data stored in the configuration module to local storage. It then
verifies that each memory location within the module can be read from and written to. Once
complete, it restores the original data back into the configuration module and reports the pass/fail
status with a message as shown below.
Test selection 5, 'Output Voice Message', generates the voice message: "Autopilot baro set fail,
set manually" on the audio output. NOTE: This test only applies to versions of the FCC with voice
messaging capability.
Test selection 6, 'Toggle Screen Refresh', allows the user to ENABLE or DISABLE continual
update of data to the remote terminal display. When ENABLED, the data values on the Analog
Input screens will be constantly updated. When DISABLED, the analog data will only be sampled
once upon entry into the analog screens.
Revision 2, Dec/2002
CS:15574F02
BENDIX/KING
KAP 140
System mode: Diagnostic
Perform Analog Tests
--------------------
1 - Display All Segments
2 - Display No Segments
3 - Display 'RUN OUT FOR ALE'
4 - Perform NVM Test
5 - Output Voice Message
6 - Toggle Screen Refresh
Press key for desired option (<CR> to exit)
FIGURE 3--11 ANALOG TESTS SCREEN
Result of the specified test: PASS
- ENABLED
Page 3--23