3.3.8 ANALOG VOLTAGE INPUTS SCREEN

Pressing 'I' when the Diagnostics Menu screen is displayed will cause the Analog Inputs screen,
similar to Figure 3--9, to be displayed. Pressing 'ENTER' when this screen is displayed returns
the user to the Diagnostics Menu screen.
Adj Pot
Photocell
Dim Bus
A/C Mon
Baro set
Trim voltage
Baro Supply Voltage
+15VDC Supply
-15VDC Supply
NAV Valid
GS Valid
Roll Servo Command
This screen includes analog inputs associated with internal references with scaled values in volts.
The data values displayed are updated at 8 Hz. Also included is the unit of measure and an
indication as to whether the signal is valid.
ITEM
Adj. Pot
Photocell
Revision 2, Dec/2002
CS:15574F02
BENDIX/KING
System mode: Diagnostic
ANALOG VOLT INPUTS
Description
--------------
-------
Press CR to exit:
FIGURE 3--9 ANALOG VOLTAGE INPUTS SCREEN
KAP 140
Units
Data
Valid
------
-----
volts
2.954
1
volts
2.236
1
volts
0.000
1
volts
27.088
1
volts
0.000
1
volts
0.195
1
volts
3.984
1
volts
15.780
1
volts
-15.945 1
volts
0.190
1
volts
0.186
1
volts
0.044
1
DESCRIPTION
Adjustment potentiometer accessible through the
FCC front panel, used to make installation
adjustments.
This value is from a single turn,
270--degree
rotation
adjustment range of 0 to 5V. Validity based on
internal Analog Valid.
Photocell embedded in FCC front panel used to
automatically adjust intensity of gas--discharge
display based on ambient light level.
value will be near 0V when photocell is covered and
4.5V when photocell is exposed to bright light.
Resolution of display value is 4.9mV per bit. Validity
based on internal Analog Valid.
potentiometer
with
Displayed
Page 3--19