2.0
Safety

Safety Labels and Their Locations

Safety Labels and Their Locations
Product safety signs or labels should be replaced by the product user when they no longer are legible.
Contact either your local distributor or the product manufacturer for obtaining replacement signs or labels.
Back Panel
SAMPLE
Air Metering Orifice
DO NOT REMOVE
HOT
120V
NEUTRAL
EARTH
- 120V HEATER INPUT -
- OBSERVE POLARITY -
HOT
120V
NEUTRAL
EARTH
- 120V HEATER INPUT -
F/N LLV3E91
Top Panel
!
WARNING
Improper installation, adjustment, alteration,service
or maintenance can cause property damage, injury
or death.
Des installation réglage, modification, maintenance
ou entretien inappropriés peuvent causer des
dommages matériels, des blessures ou la mort.
This is NOT an explosion-proof heater. Where there is the
possibility of exposure to flammable vapors or dusts, consult
the local fire marshall, your insurance carrier or authorities for
approval of the proposed installation. Do NOT install in
residential or explosive environments.
This heater must be installed and serviced by trained gas
installation and service personnel only. The installation of this
heater must conform with local building codes or, in the
absence of such codes, the National Fuel Gas Code (NFPA
54).
GAS CONNECTION
Allowances must be made for the system to expand. A
flexible gas connection of approved type is required. The
connector shall be of Type 1 hose per Exhibit "A" Section B.4.,
and Figure 1 and 2. Consult manual for further instructions.
Ceci n'est PAS un radiateur antidéflagrant. En présence possible de
vapeurs ou de poussières inflammables, consulter le commissaire
des incendies local, votre compagnie d'assurance ou les autorités
compétentes pour l'approbation de l'installation projetée. NE
CONVIENT PAS aux applications résidentielles ou à tout
environnement sujet à explosion.
Ce radiateur à gaz ne doit être installé et entretenu que par du
personnel formé et qualifié à cette fin. L'installation de ce radiateur
doit être conforme aux codes locaux du bâtiment ou, en l'absence
de tels codes, du National Fuel Gas Code (NFPA 54)
RACCORDEMENT AU GAZ
Prévoir du jeu pour la dilatation du système. Un raccordement par
tube flexible approuvé pour le gaz est nécessaire. Le raccord
flexible devra être de type 1 tel qu'indiqué au schéma 'A', section
B.4., et aux figures 1 et 2 Se référer au manuel pour plus
d'information.
Read and understand the installation, operating
and maintenance instructions thoroughly before
installing or servicing this equipment.
Lire et comprendre les directives d'installation, de
fonctionnement et d'entretien avant d'installer ou
d'entretenir cet équipement
F/N: LLAC
TP-114
1 - 1/2"
TP-3014
Air Metering Orifice
RE-VERBER-RAY LOW INTENSITY INFRARED HEATER
RADIATEUR A INFRAROUGE A FAIBLE INTENSITE
FOR INDOOR INSTALLATION ONLY. NOT FOR USE IN RESIDENTIAL DWELLING.
INSTALLATION À L'EXTÉRIEUR SEULEMENT. NE PAS INSTALLER DANS UN LOGEMENT.
MODEL /MODELE NO.
INPUT BTU/H
FOR USE WITH
DX2-40-125N
125,000
NATURAL GAS
VOLTS A.C.
MANIFOLD PRESSURE
HEATER TYPE
3.5" WC
C1
120~60Hz
VERSION
STARTING AMPS.
MIN. INLET PRESSURE
4.8
5.0" WC
10/11
RUNNING AMPS.
ORIFICE SIZE
MIN. MOUNTING ANGLE:
1.1
0 DEGREES
#4 D.M.S
FOR STAINLESS STEEL UPGRADES THE
MAX. MOUNTING ANGLE:
COMBUSTION CHAMBER:
COMBUSTION TUBE IS UPGRADED TO 409
4" BC ALUMINUM
45 DEGREES
STAINLESS STEEL.
ANSI Z83.20b - 2011 CSA 2.32b - 2011 Low - Intensity Infrared Htr.
FOR INDOOR USE
ANS Z83.20b - 2011 CSA - 2011 Low - Intensity Infrared Htr.
BRANT RADIANT HEATERS LIMITED
SERIAL NO.
34 SCOTT AVE., PARIS, ONTARIO
0870 XXXX XXXX 0001
TEL: 1-519-442-7823 WWW.BRANTRADIANT.COM
!
INSTALLER
GAS
Gas Supply
Gas Supply
CONNECTION
Avoid Equipment Failure
Allowances must be made
Do Not Rotate Burner Assembly.
for the system to expand.
12"
3" (7.62cm) max displacement
45°
Éviter les pannes d'équipement
approved type is required.
(30cm)
Ne tournez pas l'assemblage du brûleur
installed on one plane, and
Mount Level/
without sharp bends, kinks,
45°
Monter de niveau
or twists is recommended.
Consult manual for further
instructions.
Rubber Hose Gas Connector,
formed into a C-shape
INSTALLER
!
Avoid Equipment Failure
Do Not Rotate Burner Assembly.
Éviter les pannes d'équipement
Ne tournez pas l'assemblage du brûleur
Mount Level/
Monter de niveau
!
DANGER
!
CAUTION
FIRE HAZARD. Always maintain published clearance to combustibles. In locations
!
Improper installation, adjustment, alteration, service or
used for the storage of combustible materials, signs must be posted. Consult manual
maintenance can cause property damage, injury or
for additional guidelines.
death.
RISQUE D'INCENDIE. Toujours respecter les dégagements prescrits de tout matériau
Des installation, réglage, modification,maintenance ou
combustible. Dans les endroits servant au stockage de matériaux combustibles, des
écriteaux doivent en avertir. Se référer au manuel pour des directives supplémentaires.
entretien inappropriés peuvent causer des dommages
matériels, des blessures ou la mort.
CLEARANCE TO COMBUSTIBLES IN INCHES (cm)
This heater can be installed in various configurations as specified in the
manual.
MODEL
MOUNTING
SIDE
BTU/h RANGE
ANGLE
BELOW
AIRCRAFT HANGARS. This heater must be installed in accordance
FRONT
BEHIND
TOP
with the latest edition of the Standard for Aircraft Hangars, ANSI/NFPA
50,000* - 60,000*
9
(23)
9
(23)
6
(15)
47
(119)
409.
45º
39
(99)
8
(20)
10
(25)
47
(119)
PUBLIC GARAGES. This heater must be installed in accordance with
W/1 side shield
29
(74)
8
(20)
6
(15)
47
(119)
the latest edition of the Standard for Parking Structures, ANSI/NFPA
W/2 side shields
9
(23)
9
(23)
6
(15)
47
(119)
20 ft. from burner
7
(18)
7
(18)
6
(15)
30
(76)
88A, or the Code for Repair Garages, ANSI/NFPA 30A or the Canadian
Natural Gas and Propane Installation Code, CSA B149.1. as per
65,000* - 75,000*
9
(23)
9
(23)
6
(15)
60
(152)
Clause 1.1.4.
45º
39
(99)
8
(20)
10
(25)
60
(152)
W/1 side shield
29
(74)
8
(20)
6
(15)
60
(152)
VENTING. This heater's venting system must comply with the following
W/2 side shields
9
(23)
9
(23)
6
(15)
60
(152)
requirements:
7
(15)
20 ft. from burner
(18)
7
(18)
6
30
(76)
• Do not exceed 20 feet vent length or place more than two (2) 90°
80,000* - 100,000*
14
14
(35)
6
(15)
66
elbows in the venting system.
(35)
(168)
45º
39
(99)
8
(20)
10
(25)
66
(168)
• Use 4-DSK Vent Kit for single sidewall venting;
• Common vented models (with Y-fitting) must be wired on the same
W/1 side shield
29
(74)
8
(20)
6
(15)
66
(168)
W/2 side shields
16
(41)
16
(41)
6
(15)
66
.(168)
control.
20 ft. from burner
7
(18)
7
(18)
6
(15)
30
(76)
• A minimum ventilation rate of 4.0 cfm/1000
Btu/H is required for unvented operation.
105,000* - 125,000*
20
(51)
20
(51)
6
(15)
76
(193)
45º
58
(147)
8
(20)
10
(25)
76
(193)
Ce radiateur peut être installé dans différentes configurations tel que
W/1 side shield
42
(107)
8
(20)
6
(15)
76
(193)
spécifié dans le manuel.
W/2 side shields
20
(51)
20
(51)
6
(15)
76
(193)
(15)
20 ft. from burner
7
(18)
7
(18)
6
30
(76)
HANGARS À AVIONS. Ce radiateur doit être installé en conformité avec
130,000* - 150,000*
24
(61)
24
(61)
6
(15)
81
(206)
a dernière édition de la norme Standard for Aircraft Hangars, ANSI/NFPA
45º
58
(147)
8
(21)
10
(25)
81
(206)
409.
W/1 side shield
42
(107)
8
(21)
6
(15)
81
(206)
GARAGES PUBLICS. Ce radiateur doit être installé en conformité avec
W/2 side shields
23
(58)
23
(58)
6
(15)
81
(206)
la dernière édition de la norme Standard for Parking Structures,
20 ft. from burner
11
(28)
11
(28)
6
(15)
44
(112)
ANSI/NFPA 88, ou du Code for Repair Garages, ANSI/NFPA 30A ou, au
155,000* - 175,000*
34
(86)
34
(86)
6
(15)
92
(234)
Canada, du Code d'installation du gaz naturel et du propane,
45º
63
(160)
8
(20)
10
(25)
92
(234)
CSA B149.1., article 1.1.4.
W/1 side shield
50
(127)
8
(20)
6
(15)
92
(234)
30
ÉVACUATION. Le système d'évacuation de ce radiateur doit
W/2 side shields
30
(76)
(76)
6
(15)
92
(234)
20 ft. from burner
11
(28)
11
(28)
(15)
44
(112)
satisfaire aux exigences suivantes:
6
180,000* - 200,000*
41
(104)
41
(104)
6
(15)
94
(239)
• Ne pas dépasser 20 pi en longueur de conduit ou utiliser plus de 2
45º
63
(160)
8
(20)
10
(25)
94
(239)
coudes à 90° dans le système d'évacuation.
54
(15)
• Utilisez l'ensemble d'évacuation RTVP-4 pour une évacuation murale
W/1 side shield
(137)
8
(20)
6
94
(239)
W/2 side shields
30
(76)
30
(76)
6
(15)
94
(239)
unique.
• Les modèles avec évacuation commne (avec raccord en Y ) doivent
20 ft. from burner
11
(28)
11
(28)
6
(15)
44
(112)
être reliés à une même commande.
TOP
TOP
TOP
TOP
• Un taux de ventilation minimal de 4 pcm/1000 Btu/H est nécessaire
pour un fonctionnement sans système d'évacuation
SIDE
SIDE
FRONT
BEHIND
FRONT
BEHIND
SIDE
SIDE
WARNING. To ensure system performance and
BELOW
BELOW
BELOW
BELOW
safety, this unit must be properly vented.
0° MOUNTING ANGLE
45° MOUNTING ANGLE
0° W/1 SIDE SHIELD
0° W/2 SIDE SHIELDS
IMPORTANT:. *Use high BTU output when determining clearances. Minimum end clearance for all models
AVERTISSEMENT. Pour assurer le rendement et le
fonctionnement sécuritaire du système, cet appareil
.
is 12 inches. Maximum mounting angle is 45°. Keep cover in place.
*IMPORTANT: Déterminer les dégagements en fonction de la capacité nette de Btu maximale. Le
doit être ventilé de façon appropriée.
dégagement minimal à l'extrémité est de 12 po pour tous les modèles. L'angle d'inclinaison maximal est de
45°. Garder le couvercle en place.
LLTCL001-1M-4/15 (BRH)
Bottom Panel
RE-VERBER-RAY LOW INTENSITY INFRARED HEATER
RADIATEUR A INFRAROUGE A FAIBLE INTENSITE
FOR INDOOR INSTALLATION ONLY. NOT FOR USE IN RESIDENTIAL DWELLING.
INSTALLATION À L'EXTÉRIEUR SEULEMENT. NE PAS INSTALLER DANS UN LOGEMENT.
MODEL /MODELE NO.
DX2-40-125N
VOLTS A.C.
MANIFOLD PRESSURE
3.5" WC
120~60Hz
MIN. INLET PRESSURE
STARTING AMPS.
5.0" WC
4.8
RUNNING AMPS.
ORIFICE SIZE
1.1
#19 D.M.S
FOR STAINLESS STEEL UPGRADES THE
COMBUSTION CHAMBER:
COMBUSTION TUBE IS UPGRADED TO 409
4" BC ALUMINUM
ANSI Z83.20b - 2011 CSA 2.32b - 2011 Low - Intensity Infrared Htr.
ANS Z83.20b - 2011 CSA - 2011 Low - Intensity Infrared Htr.
BRANT RADIANT HEATERS LIMITED
34 SCOTT AVE., PARIS, ONTARIO
TEL: 1-519-442-7823 WWW.BRANTRADIANT.COM
Do Not Rotate/ Gas Connection Label
GAS
CONNECTION
Allowances must be made
for the system to expand.
A flexible gas connection of
12"
(30cm)
approved type is required.
Rubber gas connectors
installed on one plane, and
without sharp bends, kinks,
or twists is recommended.
Consult manual for further
instructions.
Rubber Hose Gas Connector,
formed into a C-shape
WARNING
!
Improper installation, adjustment, alteration,service
FIRE HAZARD. Always maintain published clearance to combustibles. In locations
or maintenance can cause property damage, injury
used for the storage of combustible materials, signs must be posted. Consult manual
for additional guidelines.
or death.
Des installation réglage, modification, maintenance
RISQUE D'INCENDIE. Toujours respecter les dégagements prescrits de tout matériau
combustible. Dans les endroits servant au stockage de matériaux combustibles, des
ou entretien inappropriés peuvent causer des
écriteaux doivent en avertir. Se référer au manuel pour des directives supplémentaires.
dommages matériels, des blessures ou la mort.
CLEARANCE TO COMBUSTIBLES IN INCHES (cm)
This is NOT an explosion-proof heater. Where there is the
possibility of exposure to flammable vapors or dusts, consult
MODEL
MOUNTING
the local fire marshall, your insurance carrier or authorities for
BTU/h RANGE
ANGLE
approval of the proposed installation. Do NOT install in
50,000* - 60,000*
residential or explosive environments.
W/1 side shield
This heater must be installed and serviced by trained gas
W/2 side shields
installation and service personnel only. The installation of this
20 ft. from burner
heater must conform with local building codes or, in the
65,000* - 75,000*
absence of such codes, the National Fuel Gas Code (NFPA
54).
W/1 side shield
W/2 side shields
GAS CONNECTION
20 ft. from burner
Allowances must be made for the system to expand. A
80,000* - 100,000*
flexible gas connection of approved type is required. The
connector shall be of Type 1 hose per Exhibit "A" Section B.4.,
W/1 side shield
and Figure 1 and 2. Consult manual for further instructions.
W/2 side shields
20 ft. from burner
105,000* - 125,000*
Ceci n'est PAS un radiateur antidéflagrant. En présence possible de
W/1 side shield
vapeurs ou de poussières inflammables, consulter le commissaire
W/2 side shields
des incendies local, votre compagnie d'assurance ou les autorités
20 ft. from burner
compétentes pour l'approbation de l'installation projetée. NE
130,000* - 150,000*
CONVIENT PAS aux applications résidentielles ou à tout
W/1 side shield
environnement sujet à explosion.
W/2 side shields
Ce radiateur à gaz ne doit être installé et entretenu que par du
20 ft. from burner
personnel formé et qualifié à cette fin. L'installation de ce radiateur
155,000* - 175,000*
doit être conforme aux codes locaux du bâtiment ou, en l'absence
de tels codes, du National Fuel Gas Code (NFPA 54)
W/1 side shield
W/2 side shields
RACCORDEMENT AU GAZ
20 ft. from burner
Prévoir du jeu pour la dilatation du système. Un raccordement par
180,000* - 200,000*
tube flexible approuvé pour le gaz est nécessaire. Le raccord
flexible devra être de type 1 tel qu'indiqué au schéma 'A', section
W/1 side shield
B.4., et aux figures 1 et 2 Se référer au manuel pour plus
W/2 side shields
d'information.
20 ft. from burner
TOP
Read and understand the installation, operating
FRONT
SIDE
SIDE
and maintenance instructions thoroughly before
installing or servicing this equipment.
BELOW
Lire et comprendre les directives d'installation, de
0° MOUNTING ANGLE
45° MOUNTING ANGLE
fonctionnement et d'entretien avant d'installer ou
IMPORTANT:. *Use high BTU output when determining clearances. Minimum end clearance for all models
d'entretenir cet équipement
.
is 12 inches. Maximum mounting angle is 45°. Keep cover in place.
*IMPORTANT: Déterminer les dégagements en fonction de la capacité nette de Btu maximale. Le dégage-
ment minimal à l'extrémité est de 12 po pour tous les modèles. L'angle d'inclinaison maximal est de 45°.
Garder le couvercle en place.
6
DX2
INPUT BTU/H
FOR USE WITH
125,000
NATURAL GAS
HEATER TYPE
C1
VERSION
10/11
MIN. MOUNTING ANGLE:
0 DEGREES
MAX. MOUNTING ANGLE:
45 DEGREES
STAINLESS STEEL.
FOR INDOOR USE
SERIAL NO.
0870 XXXX XXXX 0001
Gas Supply
Gas Supply
3" (7.62cm) max displacement
45°
DANGER
CAUTION
!
!
Improper installation, adjustment, alteration, service or
!
maintenance can cause property damage, injury or
death.
Des installation, réglage, modification,maintenance ou
entretien inappropriés peuvent causer des dommages
matériels, des blessures ou la mort.
This heater can be installed in various configurations as specified in the
manual.
SIDE
AIRCRAFT HANGARS. This heater must be installed in accordance
FRONT
BEHIND
TOP
BELOW
with the latest edition of the Standard for Aircraft Hangars, ANSI/NFPA
9
(23)
9
(23)
6
(15)
47
(119)
409.
45º
39
(99)
8
(20)
(25)
47
(119)
10
PUBLIC GARAGES. This heater must be installed in accordance with
8
29
(74)
(20)
6
(15)
47
(119)
the latest edition of the Standard for Parking Structures, ANSI/NFPA
9
(23)
9
(23)
6
(15)
47
(119)
88A, or the Code for Repair Garages, ANSI/NFPA 30A or the Canadian
7
(18)
7
(18)
6
(15)
30
(76)
Natural Gas and Propane Installation Code, CSA B149.1. as per
9
(23)
9
(23)
6
(15)
60
(152)
Clause 1.1.4.
45º
39
(99)
8
(20)
10
(25)
60
(152)
29
(74)
(20)
(15)
60
(152)
VENTING. This heater's venting system must comply with the following
8
6
(15)
60
9
(23)
9
(23)
6
(152)
requirements:
7
(18)
7
(18)
6
(15)
30
(76)
• Do not exceed 20 feet vent length or place more than two (2) 90°
14
(35)
14
(35)
6
(15)
66
(168)
elbows in the venting system.
45º
39
(99)
8
(20)
10
(25)
(168)
• Use 4-DSK Vent Kit for single sidewall venting;
66
8
• Common vented models (with Y-fitting) must be wired on the same
29
(74)
(20)
6
(15)
66
(168)
control.
16
(41)
16
(41)
6
(15)
66
.(168)
• A minimum ventilation rate of 4.0 cfm/1000
7
(18)
7
6
(15)
30
(18)
(76)
Btu/H is required for unvented operation.
20
20
(15)
76
(51)
(51)
6
(193)
45º
58
(147)
8
(20)
10
(25)
76
(193)
Ce radiateur peut être installé dans différentes configurations tel que
8
(15)
(193)
42
(107)
(20)
6
76
spécifié dans le manuel.
20
(15)
20
(51)
(51)
6
76
(193)
7
(18)
7
(18)
6
(15)
30
(76)
HANGARS À AVIONS. Ce radiateur doit être installé en conformité avec
24
(61)
24
(61)
6
(15)
81
(206)
a dernière édition de la norme Standard for Aircraft Hangars, ANSI/NFPA
45º
58
(147)
8
(21)
10
(25)
81
(206)
409.
42
(107)
8
(21)
(15)
81
(206)
6
GARAGES PUBLICS. Ce radiateur doit être installé en conformité avec
23
6
23
(58)
(58)
(15)
81
(206)
la dernière édition de la norme Standard for Parking Structures,
11
(28)
11
(28)
6
(15)
44
(112)
ANSI/NFPA 88, ou du Code for Repair Garages, ANSI/NFPA 30A ou, au
34
(86)
34
(86)
6
(15)
92
(234)
Canada, du Code d'installation du gaz naturel et du propane,
45º
63
(160)
8
(20)
10
(25)
92
(234)
CSA B149.1., article 1.1.4.
8
50
(127)
(20)
6
(15)
92
(234)
30
ÉVACUATION. Le système d'évacuation de ce radiateur doit
30
(76)
(76)
6
(15)
92
(234)
11
11
(28)
(15)
(112)
satisfaire aux exigences suivantes:
(28)
6
44
41
41
6
(15)
• Ne pas dépasser 20 pi en longueur de conduit ou utiliser plus de 2
(104)
(104)
94
(239)
(25)
coudes à 90° dans le système d'évacuation.
45º
63
(160)
8
(20)
10
94
(239)
• Utilisez l'ensemble d'évacuation RTVP-4 pour une évacuation murale
54
(137)
8
(20)
6
(15)
94
(239)
unique.
30
(76)
30
(76)
6
(15)
94
(239)
11
11
(28)
(15)
(112)
• Les modèles avec évacuation commne (avec raccord en Y ) doivent
(28)
6
44
être reliés à une même commande.
TOP
TOP
TOP
• Un taux de ventilation minimal de 4 pcm/1000 Btu/H est nécessaire
pour un fonctionnement sans système d'évacuation
BEHIND
FRONT
BEHIND
SIDE
SIDE
WARNING. To ensure system performance and
BELOW
BELOW
safety, this unit must be properly vented.
BELOW
0° W/1 SIDE SHIELD
0° W/2 SIDE SHIELDS
AVERTISSEMENT. Pour assurer le rendement et le
fonctionnement sécuritaire du système, cet appareil
doit être ventilé de façon appropriée.
Safety and Clearance Labels
F/N LLTCL001
F/N: LLLOGO1
Series
Rating
Plate
45°
LLTCL001-1M-4/15 (BRH)