Safety Labels And Locations - Brant Radiant Heaters DX2-20-60 User Manual

Gas-fired infrared tube heater
Table of Contents

Advertisement

DX2
Series
Safety Labels and Their Locations
Product safety signs or labels should be replaced by the product user when they no longer are legible.
Contact either your local distributor or the product manufacturer for obtaining replacement signs or labels.
SAMPLE
TP-114
Air Metering Orifice
TP-3014
DO NOT REMOVE
Back Panel
Top Panel
F/N: LLAC
1 - 1/2"
Air Metering Orifice
RE-VERBER-RAY LOW INTENSITY INFRARED HEATER
RADIATEUR A INFRAROUGE A FAIBLE INTENSITE
FOR INDOOR INSTALLATION ONLY. NOT FOR USE IN RESIDENTIAL DWELLING.
INSTALLATION À L'EXTÉRIEUR SEULEMENT. NE PAS INSTALLER DANS UN LOGEMENT.
MODEL /MODELE NO.
INPUT BTU/H
FOR USE WITH
NATURAL GAS
DX2-40-125N
125,000
VOLTS A.C.
MANIFOLD PRESSURE
HEATER TYPE
120~60Hz
3.5" WC
C1
MIN. INLET PRESSURE
VERSION
STARTING AMPS.
4.8
5.0" WC
10/11
RUNNING AMPS.
ORIFICE SIZE
MIN. MOUNTING ANGLE:
1.1
#19 D.M.S
0 DEGREES
FOR STAINLESS STEEL UPGRADES THE
MAX. MOUNTING ANGLE:
COMBUSTION CHAMBER:
COMBUSTION TUBE IS UPGRADED TO 409
45 DEGREES
4" BC ALUMINUM
STAINLESS STEEL.
ANSI Z83.20b - 2011 CSA 2.32b - 2011 Low - Intensity Infrared Htr.
FOR INDOOR USE
ANS Z83.20b - 2011 CSA - 2011 Low - Intensity Infrared Htr.
BRANT RADIANT HEATERS LIMITED
SERIAL NO.
34 SCOTT AVE., PARIS, ONTARIO
0870 XXXX XXXX 0001
TEL: 1-519-442-7823 WWW.BRANTRADIANT.COM
SAFETY INFORMATION / INFORMATIONS DE SÉCURITÉ
WARNING
AVERTISSEMENT
FAILURE TO COMPLY WITH THE STATED
LE DÉFAUT DE SE CONFORMER AUX DONNÉES DES
CLEARANCES TO COMBUSTIBLES
DÉGAGEMENTS AUX MATIÈRES INFLAMMABLES
COULD RESULT IN PROPERTY DAMAGE,
PEUT RÉSULTER EN BLESSURES PERSONNELLES
PERSONAL INJURY AND/OR DEATH.
ET/OU DOMMAGES SUR LA PROPRIÉTÉ.
CLEARANCES TO COMBUSTIBLES IN. & CM / DÉGAGEMENTS AUX MATIÈRES COMBUSTIBLES PCE & CM
MOUNTING
SIDE
MODEL NO.
ANGLE
BEHIND
IN FRONT
TOP
BELOW
ANGLE DE
CÔTE
MODÈLES
MONTAGE
ARRIÈRE
AVANT
DESSUS
DESSOUS
IN.
IN.
IN.
IN.
UNITS
DEGREES
PCE
CM
PCE
CM
PCE
CM
PCE
CM
DX, AG1, SE -
9
22.9
9
22.9
6
15.2
47
119.4
50,000 N or P
45°
8
20.3
39
99.1
10
25.4
47
119.4
W/1 SIDE SHIELD
8
20.3
29
73.7
6
15.2
47
119.4
W/2 SIDE SHIELDS
9
22.9
9
22.9
6
15.2
47
119.4
DX, AG1, SE -
9
22.9
9
22.9
6
15.2
47
119.4
60,000 N or P
45°
8
20.3
39
99.1
10
25.4
47
119.4
W/1 SIDE SHIELD
8
20.3
29
73.7
6
15.2
47
119.4
W/2 SIDE SHIELDS
9
22.9
9
22.9
6
15.2
47
119.4
DX, HL, SE, ST, AG1, AG2 -
9
22.9
9
22.9
6
15.2
60
152.4
TOP
75,000 N or P
45°
8
20.3
39
99.1
10
25.4
60
152.4
TOP
W/1 SIDE SHIELD
8
20.3
29
73.7
6
15.2
60
152.4
W/2 SIDE SHIELDS
9
22.9
9
22.9
6
15.2
60
152.4
DX, HL, SE, ST, AG1, AG2 -
14
35.6
14
35.6
6
15.2
66
167.6
100,000 N or P
45°
8
20.3
39
99.1
10
25.4
66
167.6
SIDE
SIDE
W/1 SIDE SHIELD
8
20.3
29
73.7
6
15.2
66
167.6
SIDE
SIDE
W/2 SIDE SHIELDS
16
40.6
16
40.6
6
15.2
66
167.6
DX, HL, SE, ST, AG1, AG2 -
20
50.8
20
50.8
6
15.2
76
193
125,000 N or P
45°
8
20.3
58
147.3
10
25.4
76
193
W/1 SIDE SHIELD
8
20.3
42
106.7
6
15.2
76
193
BELOW
W/2 SIDE SHIELD
20
50.8
20
50.8
6
15.2
76
193
BELOW
20 ft or 6.1 m
0° MOUNTING ANGLE
DOWNSTREAM
0° W/1 SIDE SHIELD
OF BURNER
7
17.8
7
17.8
6
15.2
30
76.2
DX, HL, SE, ST, AG1, AG2 -
24
61
24
61
6
15.2
81
205.7
TOP
150,000 N or P
45°
8
20.3
58
147.3
10
25.4
81
205.7
TOP
W/1 SIDE SHIELD
8
20.3
42
106.7
6
15.2
81
205.7
W/2 SIDE SHIELDS
23
58.4
23
58.4
6
15.2
81
205.7
DX, HL, SE, ST -
34
86.4
34
86.4
6
15.2
92
233.7
175,000 N or P
45°
8
20.3
63
160
10
25.4
92
233.7
SIDE
SIDE
FRONT
BEHIND
W/1 SIDE SHIELD
8
20.3
50
127
6
15.2
92
233.7
W/2 SIDE SHIELDS
30
76.2
30
76.2
6
15.2
233.7
92
DX, HL, SE, ST -
41
104.1
41
104.1
6
15.2
94
238.8
200,000 N or P
45°
8
20.3
63
160
10
25.4
94
238.8
W/1 SIDE SHIELD
8
20.3
54
137.2
6
15.2
94
238.8
BELOW
W/2 SIDE SHIELDS
30
76.2
30
76.2
6
15.2
94
238.8
BELOW
45° MOUNTING ANGLE
20 ft or 6.1 m
0° W/2 SIDE SHIELDS
DOWNSTREAM
OF BURNER
11
27.9
11
27.9
6
15.2
44
111.8
BR-VCF
MIN. 12 IN.or 30.5 cm
END CLEARANCE
TO CEILING
12 IN. or 30.5 cm
CLEARANCE
TO WALL OR
COMBUSTIBLES
20 ft or 6.1 m
FIRST 20 ft
DOWNSTREAM
BURNER
or 6.1 m
& BEYOND
CAUTION: KEEP COVER IN PLACE. REMOVE FOR SERVICE ONLY.
ATTENTION: GARDER LE COUVERCLE EN PLACE. N'ENLEVER QUE POUR L'ENTRETIEN
Bottom Panel
2.0
Safety
RE-VERBER-RAY LOW INTENSITY INFRARED HEATER
RADIATEUR A INFRAROUGE A FAIBLE INTENSITE
FOR INDOOR INSTALLATION ONLY. NOT FOR USE IN RESIDENTIAL DWELLING.
INSTALLATION À L'EXTÉRIEUR SEULEMENT. NE PAS INSTALLER DANS UN LOGEMENT.
MODEL /MODELE NO.
DX2-40-125N
VOLTS A.C.
MANIFOLD PRESSURE
3.5" WC
120~60Hz
MIN. INLET PRESSURE
STARTING AMPS.
5.0" WC
4.8
RUNNING AMPS.
ORIFICE SIZE
1.1
#19 D.M.S
FOR STAINLESS STEEL UPGRADES THE
COMBUSTION CHAMBER:
COMBUSTION TUBE IS UPGRADED TO 409
4" BC ALUMINUM
ANSI Z83.20b - 2011 CSA 2.32b - 2011 Low - Intensity Infrared Htr.
ANS Z83.20b - 2011 CSA - 2011 Low - Intensity Infrared Htr.
BRANT RADIANT HEATERS LIMITED
34 SCOTT AVE., PARIS, ONTARIO
TEL: 1-519-442-7823 WWW.BRANTRADIANT.COM
SAFETY INFORMATION / INFORMATIONS DE SÉCURITÉ
WARNING
AVERTISSEMENT
FAILURE TO COMPLY WITH THE STATED
LE DÉFAUT DE SE CONFORMER AUX DONNÉES DES
CLEARANCES TO COMBUSTIBLES
DÉGAGEMENTS AUX MATIÈRES INFLAMMABLES
COULD RESULT IN PROPERTY DAMAGE,
PEUT RÉSULTER EN BLESSURES PERSONNELLES
PERSONAL INJURY AND/OR DEATH.
ET/OU DOMMAGES SUR LA PROPRIÉTÉ.
CLEARANCES TO COMBUSTIBLES IN. & CM / DÉGAGEMENTS AUX MATIÈRES COMBUSTIBLES PCE & CM
SIDE
MOUNTING
MODEL NO.
ANGLE
BEHIND
IN FRONT
TOP
CÔTE
ANGLE DE
MODÈLES
MONTAGE
ARRIÈRE
AVANT
DESSUS
IN.
IN.
IN.
UNITS
DEGREES
PCE
CM
PCE
CM
PCE
CM
DX, AG1, SE -
9
22.9
9
22.9
6
15.2
50,000 N or P
45°
8
20.3
39
99.1
10
25.4
W/1 SIDE SHIELD
8
20.3
29
73.7
6
15.2
W/2 SIDE SHIELDS
9
22.9
9
22.9
6
15.2
DX, AG1, SE -
9
22.9
9
22.9
6
15.2
60,000 N or P
45°
8
20.3
39
99.1
10
25.4
W/1 SIDE SHIELD
8
20.3
29
73.7
6
15.2
W/2 SIDE SHIELDS
9
22.9
9
22.9
6
15.2
DX, HL, SE, ST, AG1, AG2 -
9
22.9
9
22.9
6
15.2
75,000 N or P
45°
8
20.3
99.1
10
25.4
39
TOP
W/1 SIDE SHIELD
8
20.3
29
73.7
6
15.2
W/2 SIDE SHIELDS
9
22.9
9
22.9
6
15.2
DX, HL, SE, ST, AG1, AG2 -
14
35.6
14
35.6
6
15.2
100,000 N or P
45°
8
20.3
39
99.1
10
25.4
SIDE
SIDE
W/1 SIDE SHIELD
8
20.3
29
73.7
6
15.2
W/2 SIDE SHIELDS
16
40.6
16
40.6
6
15.2
DX, HL, SE, ST, AG1, AG2 -
20
50.8
50.8
6
15.2
20
125,000 N or P
45°
8
20.3
58
147.3
10
25.4
W/1 SIDE SHIELD
8
20.3
42
106.7
6
15.2
W/2 SIDE SHIELD
20
50.8
20
50.8
6
15.2
BELOW
20 ft or 6.1 m
0° MOUNTING ANGLE
DOWNSTREAM
OF BURNER
7
17.8
7
17.8
6
15.2
DX, HL, SE, ST, AG1, AG2 -
24
61
24
61
6
15.2
TOP
150,000 N or P
45°
8
20.3
58
147.3
10
25.4
W/1 SIDE SHIELD
8
20.3
42
106.7
6
15.2
W/2 SIDE SHIELDS
23
58.4
23
58.4
6
15.2
DX, HL, SE, ST -
34
86.4
34
86.4
6
15.2
175,000 N or P
20.3
160
10
25.4
45°
8
63
FRONT
BEHIND
W/1 SIDE SHIELD
8
20.3
50
127
6
15.2
W/2 SIDE SHIELDS
30
76.2
30
76.2
6
15.2
DX, HL, SE, ST -
41
104.1
41
104.1
6
15.2
200,000 N or P
45°
8
20.3
63
160
10
25.4
W/1 SIDE SHIELD
8
20.3
54
137.2
6
15.2
BELOW
W/2 SIDE SHIELDS
30
76.2
30
76.2
6
15.2
45° MOUNTING ANGLE
20 ft or 6.1 m
DOWNSTREAM
OF BURNER
11
27.9
11
27.9
6
15.2
MIN. 12 IN.or 30.5 cm
TO CEILING
END CLEARANCE
20 ft or 6.1 m
FIRST 20 ft
DOWNSTREAM
or 6.1 m
BURNER
& BEYOND
CAUTION: KEEP COVER IN PLACE. REMOVE FOR SERVICE ONLY.
ATTENTION: GARDER LE COUVERCLE EN PLACE. N'ENLEVER QUE POUR L'ENTRETIEN
Clearance to Combustibles
F/N: LLLOGO1
7

Safety Labels and Locations

INPUT BTU/H
FOR USE WITH
125,000
NATURAL GAS
HEATER TYPE
C1
VERSION
10/11
MIN. MOUNTING ANGLE:
0 DEGREES
MAX. MOUNTING ANGLE:
45 DEGREES
STAINLESS STEEL.
FOR INDOOR USE
SERIAL NO.
0870 XXXX XXXX 0001
BELOW
DESSOUS
IN.
PCE
CM
47
119.4
47
119.4
119.4
47
47
119.4
47
119.4
47
119.4
47
119.4
47
119.4
60
152.4
152.4
60
TOP
60
152.4
60
152.4
66
167.6
66
167.6
66
167.6
SIDE
SIDE
66
167.6
193
76
76
193
76
193
76
193
BELOW
0° W/1 SIDE SHIELD
30
76.2
81
205.7
TOP
81
205.7
81
205.7
81
205.7
92
233.7
233.7
92
SIDE
SIDE
92
233.7
92
233.7
94
238.8
94
238.8
94
238.8
BELOW
94
238.8
0° W/2 SIDE SHIELDS
44
111.8
BR-VCF
12 IN. or 30.5 cm
CLEARANCE
TO WALL OR
COMBUSTIBLES
Label.
Rating
Plate

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents