Laser Power-Up, Mode Selection, Light-Out Control Area; Programming Mode Test Area - Raycus RFL-C20000M-CE User Manual

Continuous-wave fiber laser
Table of Contents

Advertisement

8.3.3 Laser power-up, mode selection, light-out control area

Laser power-up, mode selection, light out control display area is as in Figure 33, the display content
is as in Table 15.
Figure 33 Laser power-on, mode selection, light out control display area
Table 15 Laser power-on, mode selection, light out control display area explanation
Display
Main power button
External control
mode
AD mode
Red guide beam
Power correction
Eliminate alarm
Laser ON
Laser OFF

8.3.4 Programming mode test area

The laser programming mode test area interface is as Figure 36, in which the „START‟ button is
used to test the programming of the programming mode. This function can only run internal mode (when
external mode is turned off). Enter the current pre-tested programming number in the digital text box and
click the START button.
Click ON, main power on; click OFF, main power off
Click ON, activate laser external control; Click OFF, shut laser external control; mode
power-off memory automatically
Click ON, AD analog mode on; click OFF, AD analog mode off;
mode power-off memory automatically
Click ON, red guide beam on; click OFF, red guide beam off
Click ON, activate laser power correction mode; click OFF, shut laser power correction mode;
mode power-off memory automatically
Eliminate current laser alarm
Laser is in output
Laser is off
Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C20000M-CE
explanation
51