Checking Generator Brushes; Battery Replacement - Miller Big Blue Air Pak 600 Owner's Manual

Table of Contents

Advertisement

8-4. Checking Generator Brushes

8-5. Battery Replacement

OM-275624 Page 46
.
Complete Parts List available at www.MillerWelds.com
New Length:
1.25 in. (32 mm)
Replace
Damaged Brushes
Larger Battery
Smaller Battery
Minimum Length:
5/8 in. (16 mm)
Tools Needed:
1
!
Stop engine and let cool.
1
Generator Brush
Mark and disconnect leads at brush hold-
er cap. Remove brushes.
Replace brushes if damaged or if brush
material is at or near minimum length.
1
GenBrush1 2014−10 / Ref 190 823
!
Stop engine.
1
Battery Locator Bracket
Mounting Holes
Access battery as shown in Section
5-4. Disconnect battery.
Remove J-bolts securing battery
and remove battery.
Battery locator brackets can be
moved to accommodate batteries
of different physical sizes.
Install and secure replacement bat-
tery.
!
Connect negative (−) battery
cable last.
255 858

Advertisement

Table of Contents
loading

Table of Contents