22. Pour the desired amount of media into the
cabinet through one of the side doors. DO
NOT overfill.
23. Wait 24 hours for the silicone sealant to fully
setup and dry. Otherwise, when the machine
is turned on and media blasting begins, the
seal may be broken, causing leakage.
24. Inspect all seals, hose clamps, glove clamps,
and window seals for any potential leaks.
Correct as required.

Test Run

Once assembly is complete, test run the machine
to ensure it is properly connected to power and
safety components are functioning correctly.
If you find an unusual problem during the test run,
immediately stop the machine, disconnect it from
power, and fix the problem BEFORE operating the
machine again. The Troubleshooting table in the
SERVICE section of this manual can help.
The Test Run consists of verifying the following: 1)
The dust collector powers up and runs correctly,
2) the ON/OFF button works correctly, 3) the air
system, controls, and lights work correctly, and 4)
there are no air leaks.
Serious injury or death can result from
using this machine BEFORE understanding
its controls and related safety information.
DO NOT operate, or allow others to operate,
machine until the information is understood.
DO NOT start machine until all preceding
setup instructions have been performed.
Operating an improperly set up machine
may result in malfunction or unexpect-
ed results that can lead to serious injury,
death, or machine/property damage.
Model G0708 (Mfd. Since 12/23)
To test run the machine:
Clear all setup tools away from machine.
1.
Make sure that the power switch is in the
2.
OFF position (see Figure 17).
ON
OFF
Figure 17. ON/OFF switch.
Connect machine to power supply.
3.
Verify that the machine operates correctly by
4.
pushing the ON button.
—When operating correctly, the dust collector
runs smoothly with little or no vibration or
rubbing noises and LED lights illuminate.
Press the OFF button.
5.
Put on safety glasses, and connect the blast
6.
cabinet to the air supply.
Adjust the regulator knob to 120 PSI as
7.
shown on the gauge.
Close all doors, grasp the blast gun and
8.
press the foot pedal. Air should exit from the
blast gun.
Note: If, after this test, regulator gauge
needle drops more than a few PSI when you
press foot pedal, verify that air supply is not
restricted. If set up correctly, blast gun media
suction tube should draw 15-17 inches of
mercury on manometer.
Listen for air leaks, and use solution of warm
9.
water and dish soap on any areas where
possible leaks may be located. Correct and
reseal as required.
10. Adjust air pressure down to 60 PSI, discon-
nect air supply, and disconnect machine from
power.
-19-