22. Pour the desired amount of media into the
cabinet through one of the side doors. DO
NOT overfill.
23. Wait 24 hours for the silicone sealant to fully
setup and dry. Otherwise, when the machine
is turned on and media blasting begins, the
seal may be broken, causing leakage.
24. Inspect all seals, hose clamps, glove clamps,
and window seals for any potential leaks.
Correct as required.
Model G0708 (Mfd. Since 1/15)

Test Run

Once the assembly is complete, test run your
machine to make sure it runs properly and is
ready for regular operation. The test run consists
of verifying the following: 1) The dust collector
powers up and runs correctly, 2) the ON/OFF but-
ton works correctly, 3) the air system, controls,
and the lamp work correctly, 4) and that there are
no air leaks.
If, during the test run, you cannot easily locate
the source of an unusual noise or vibration, stop
using the machine immediately, then review
Troubleshooting on Page 30.
If you cannot find a remedy, contact our Tech
Support at (570) 546-9663 for assistance.
Before starting the machine, make sure you
have performed the preceding assembly
and adjustment instructions, and you have
read through the rest of the manual and
are familiar with the various functions and
safety features on this machine. Failure to
follow this warning could result in serious
personal injury or even death!
To test run the machine:
1.
Make sure you understand the safety instruc-
tions at the beginning of the manual and that
the machine is setup properly.
2.
Make sure all tools and objects used during
setup are cleared away from the machine.
3.
Make sure that the power switch is in the
OFF position (see Figure 17).
ON
OFF
Figure 17. ON/OFF switch.