9.22 FAN COVER
FRONT (hot air circulation)
44/56
Loosen the bolt that holds the hot
air circulation fan.
Remove it by pulling it outwards.
Disconnect the motor connector.
Using pliers, release the spring
keeping the belt tensioner in
tension.
Remove the belt from the tensioner
belt and motor axis.
Loosen the screws that hold the
front and rear motor fastening rods,
lift them up by rotating them and
remove them by pulling them off the
rear hook.
Disconnect the temperature
probe (you don't need to
remove it).
Loosen the 2 screw fixing
screws.
Raise and pull out the screw.
Loosen the 2 screws that hold the
inverter motor board support rod.
Pull it upwards and remove it.
Slightly rotate the whole motor unit.
Lift it up and remove.
BACK (cold air circulation)
Disconnect the condenser.
Loosen the screw fixing screw.
Raise and pull out the screw.
Technical Support MP
DISASSEMBLY
599 796-724 Rev.0.2