5
5.7 Check coolant level
Important
• Before proceeding with operation, read
Danger
• For safety precautions see
NOTE : Before proceeding with any operation on the engine, stop it and
allow it to cool.
Warning
• Presence of steam pressurized coolant danger of burn.
NOTE : Component not necessarily supplied by KOHLER .
1. Start the engine without the radiator cap A .
2. Top liquid up until the pipes inside the radiator are covered by
about 5 mm.
3. Top up if necessary.
4. Do not overfill the radiator, but leave room for the coolant to
expand.
5. Reinstall radiator cap A
6. For engines equipped with expansion tank (B) , check that the fluid
is until reaching the max level mark
NOTE : For coolant filling see
Warning
• Before starting make sure that the radiator cap and cap, if present,
are installed correctly to avoid spillage of liquid or vapour at high
temperatures.
5.8 Filter cartridge and fuel pre-filter check
Important
•
Before proceeding with operation, read
Warning
•
For safety precautions see
When turn on lights on control water filter cartridge fuel:
1. Gently loosen the wing screw A without removing it.
2. Drain the water if present.
3. Re-tighten the wing screw A as soon as the fuel begins to flow.
EN
44
Par. 3.2.2
Chap. 3
.
Par. 4.6
.
Cap. 3
.
.
Fig 5.7
Par. 3.2.2
.
5.7