Control Panel - Supermicro Storage SuperServer SSG-641E-E1CR36H User Manual

Table of Contents

Advertisement

Control Panel

Feature
Description
The main power switch applies or removes primary power from the power supply to the server
Power button
but maintains standby power.
Reset Button
The reset button is used to reboot the system
Indicates power is being supplied to the system power supply units. This LED is illuminated
Power LED
when the system is operating normally.
Drive LED
Indicates activity on the storage drives when flashing.
NIC LEDs
Indicates network activity on LANs when flashing.
Power Fail LED
Indicates a power supply module has failed.
Information LED
Alerts operator to several states, as noted in the table below.
Color, Status
Red, solid
Red, blinking at 1 Hz
Red, blinking at 0.25 Hz
Red, solid, with Power LED blinking
green
Blue and red, blinking at 10 Hz
Blue, solid
Blue, blinking at 1 Hz
Blue, blinking at 2 Hz
Blue, blinking at 4 Hz
Blue, blinking at 10 Hz with Power
LED blinking green
Figure 1-2. Control Panel
Control Panel Features
Information LED
Description
An overheat condition has occurred.
Fan failure, check for an inoperative fan.
Power failure, check for a non-operational power
supply.
Fault detected
Recovery mode
UID has been activated locally to locate the
server in a rack environment.
UID has been activated using the BMC to locate
the server in a rack environment.
BMC is resetting
BMC is setting factory defaults
BMC/BIOS firmware is updating
12
Chapter 1: Introduction
Power Button
Reset Button
Power LED
Drive LED
NIC (LAN1) LED
NIC (LAN2) LED
Information LED
Power Fail LED

Advertisement