Transcal
Rinsing
CHEMICAL PROBE LINE RINSE PROCEDURE
1. Fill a suitable container with fresh water (and any
applicable decontaminating agent), at least 50
litres of fresh water should be sucked through for
sufficient cleaning.
2. Remove the cam lever plug and connect the
chemical probe line to the cam lever socket at
the Transcal station.
3. Turn Chemical Probe valve to ON.
4. Place the probe into the container with fresh
water and open the valve on the chemical probe.
5. Turn the yellow t-handle on the Transcal station
to 'EMPTY'.
6. Operate the Transcal venturi around 85 PSI.
7. The fresh water should now transfer to the
Transcal tank and then into the main spray tank
cleaning the lines from the chemical probe to the
Transcal tank and to the main spray tank.
When finished:
• Turn the valve on the chemical probe line OFF.
• Turn the chemical probe valve OFF.
• Turn the yellow t-handle OFF.
• Turn the venturi valve OFF.
• Ensure that the agitator valve is ON.
Disconnect the line from the Transcal tank to the
probe from the cam lever fitting and replace the
cam plug.
MICROMATIC LINE RINSE PROCEDURE
1. Connect the Micromatic coupler to the
Micromatic rinsing socket.
2. Connect the envirodrum suction line to the cam
lever socket on the sprayer.
3. Turn Chemical Probe valve to ON.
4. Open the 'Envirorum Coupling Rinse' valve on the
external water delivery station so that the fresh
water cleans both the Micromatic coupler and the
line to the Transcal tank.
5. Turn the venturi ON at 85 PSI.
Prairie 1500-3000L Operator's Manual MY17-MY19 - REV 0
6. The fresh water will now rinse through the
Micromatic fittings to the Transcal tank and then
into the main spray tank.
7. When there has been sufficient cleaning with
fresh water (at least 5 minutes of cleaning), close
the Envirodrum Coupling Rinse valve.
When finished:
• Turn the chemical probe valve OFF.
• Turn the yellow t-handle OFF.
• Turn the venturi valve OFF.
• Ensure that the agitator valve is ON.
TRANSCAL TANK RINSE PROCEDURE
1. Keep both the sprayer pump and Transcal venturi
system operating at 85 PSI.
2. Ensure that the tank is vented by turning the
yellow t-handle on the Transcal station to 'EMPTY'.
3. Turn the 'Transcal Flush' valve on the external
water delivery station ON.
4. The tank and sight tube should be rinsed and the
rinsate transferred to the main spray tank.
5. Rinse the Transcal tank for as long as
recommended on the chemical label, or at least
two minutes.
6. Close the 'Transcal Flush' valve when tank is
sufficiently rinsed and the rinsate should all have
been transferred to the main spray tank.
TANK VENTING PROCEDURE
1. Turn off venturi.
2. Open probe ball valve.
3. Open Transcal ball valve to empty Transcal.
4. Vent for 30 seconds then close.