Table of Contents

Advertisement

The Local interface is displayed. See Figure 4-3.
Configure parameters, and for the detailed description, see Table 4-3.
Parameter
Unlock Responding
Interval
Unlock Period
Door Sensor Check
Time
First Unlock
Command
Door Contact Type
Click Save.

System

This section introduces how to configure the date format, time format, and the NTP server.
On the main interface (Figure 3-1), select Local Setting > System.
The System interface is displayed. See Figure 4-4.
Table 4-3 Local access control parameter description
Description
The time interval to unlock again after the previous unlock, and the
unit is second.
The time amount for which the lock stays open after unlock, and
the unit is second.
If you have installed door sensor, then you can configure the time
period, and If the unlock time exceeds the Door Sensor Check
Time, the door sensor alarm is triggered, and the alarm will be sent
to the management center.
Select the Enable check box, and the door will not be locked
until the door sensor contacts each other.
If you do not select the Enable check box, the door will be
locked after the Unlock Period finishes.
You can connect a third-party phone such as SIP phone to your
VTO, and use the command to open the door remotely.
Select NC or NO according to the lock you use.
Local
Local Setting 10

Advertisement

Table of Contents
loading