Miller Maxstar 300 DX Owner's Manual page 41

Hide thumbs Also See for Maxstar 300 DX:
Table of Contents

Advertisement

**Impulse HF Start parameters for each program (1-4)
MAXSTAR:
*DYNASTY:
DC:
AC:
* DYNASTY parameter selection only
** Parameter adjusted using a power up configuration only
*** Parameter used with the automation option (LX models only)
4-17. Resetting Unit To Factory Default Settings (All Models)
1
2
Amperage
Time
Polarity
Amperage
Time
Polarity
Amperage
Time
30 A
3 mS
EN
30 A
3 mS
EP
40 A
40 mS
3
Or
V
Rear Panel
5 – 200 Amps
1 – 200 Milliseconds
EP / EN
5 – 200 Amps
1 – 200 Milliseconds
EP / EN
5 – 200 Amps
1 – 200 Milliseconds
1
Process Switch Pad
2
Output Switch Pad
3
Adjust Switch Pad
4
Power Switch
To reset all welding power source
functions to original factory settings,
lockout feature must be off (see Sec-
tion 4-21). Next turn power on, then
press the Process, Output, and Ad-
just switch pads before the software
version clears the meters, and hold
the switch pads until software ver-
sion clears the meters.
4
OM-2222 Page 35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Maxstar 300 sdMaxstar 300 lx

Table of Contents