3-9. Automation Connection (LX Models)
F
E
D
G
J
J
C
H
I
B
A
A - Closure to D starts the weld cycle. Opening closure stops weld cycle. Durning 2T operation, a momentary closure (greater than 100 ms, but
less than 3/4 seconds) starts and stops weld output.
B - Closure to D turns on gas. This input will override Postflow, but if a Preflow time is entered, the Preflow cycle will time out before arc initia-
tion.
C - Closure to D must be maintained at all times. If the closure between pins C and D is broken, an output disable occurs, Postflow begins to
time out, and HELP 13 will be displayed on the meters.
Outputs are isolated open-collector transistor which are able to conduct 20 mA of current and 27 VDC peak.
Final Slope - output is on when in Final Slope.
Pulse Lockout - output is on when in Initial Amperage, Initial Slope, Final Slope, Final Amperage, and when the pulse frequency is less than 10
Hz.
Arc On - output is on when the contactor is on and there is less than 50 load volts.
Socket
A
Start/Stop
B
Gas
C
Output Disable
D
Chassis ground
E
Final slope – collector
F
Final slope – emitter
G
Pulse lockout – collector
H
Pulse lockout – emitter
ST-802 137-A
ST-802 137-A
I
Valid arc – collector
J
Valid arc – emitter
Definitions Of Inputs And Outputs
Inputs
Outputs
Socket Information For 10-Pin Receptacle RC2
OM-2222 Page 19