3-1. Specifications
A. For Multivoltage Units
Input
Rated Output at
Power
60% Duty Cycle
Three-
250 A @ 30 VDC,
Phase
60% Duty Cycle
Single-
200 A @ 28 VDC,
Phase
60% Duty Cycle
*While idling
Sense voltage for Stick and Lift-Arc present
Note: This unit is equipped with Auto-Link
the primary voltage being applied (230 to 460 V), without the need for manually linking primary voltage terminals.
B. For Single Voltage Units
Welding
Rated Output at
Amperage
60% Duty Cycle
Range
250 A @ 30 VDC,
5 - 300
60% Duty Cycle
*While idling
Sense voltage for Stick and Lift-Arc present
3-2. Volt-Ampere Curves
SECTION 3 – INSTALLATION
Welding
Max.
Amperage
Amperage
Open-Circuit
Open-Circuit
Range
Voltage
95
5 - 300
6 -10
95
5 - 300
6 - 10
R.
Auto-Link is an internal inverter power source circuit that automatically links the power source to
Max.
Open-Circuit
At Rated Output,
Voltage
50Hz - Three-Phase 400 V
95
6 - 10
Amperes Input At
Rated Output, 60Hz
KVA
KVA
230
460
25.4
16.2
12.8
0.23*
0.14*
0.11*
40.2
9.3
-–
0.32*
0.11*
Amperes Input
KVA
16.9
11.7
0.15*
0.10*
KW
KW
Dimensions
Dimensions
8.8
0.06*
H: 17 in (432 mm)
W: 12-1/2 in (318 mm)
6.8
D: 24 in (610 mm)
0.06*
KW
Dimensions
H: 17 in (432 mm)
8.6
W: 12-1/2 in (318 mm)
0.03*
D: 24 in (610 mm)
Volt-ampere curves show minimum
and maximum voltage and amper-
age output capabilities of welding
power source. Curves of other set-
tings fall between curves shown.
ST-190 014
OM-2222 Page 13
Net
Weight
82 lb
(37 kg)
100 lb
100 lb
(45 kg)
w/aux.
power
Net
Weight
82 lb
(37 kg)
100 lb
(45 kg)
w/aux.
power

Advertisement

Table of Contents
loading

This manual is also suitable for:

Maxstar 300 sdMaxstar 300 lx

Table of Contents