3-12. Stick DCEP (Direct Current Electrode Positive) Connections
3-13. Electrical Service Guide
A. For Multivoltage Units
NOTE
Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
Min Input Conductor Size In AWG/Kcmil
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG/Kcmil
Reference: 1996 National Electrical Code (NEC).
B. For Single Voltage Units
Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
Min Input Conductor Size In AWG/Kcmil
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG/Kcmil
Reference: 1996 National Electrical Code (NEC).
1
2
Actual input voltage cannot exceed ± 10% of indicated required input voltage. If
actual input voltage is outside of this range, no output is available.
Y Turn off power before mak-
1
Connect work lead to negative weld
output terminal.
2
Connect electrode holder to posi-
tive weld output terminal.
3
If desired, connect remote control
to Remote 14 receptacle (see Sec-
tion 3-7).
3
Three-Phase
230
25
50
10
123 (38)
197 (60)
10
ing connections.
Negative (–) Weld Output
Terminal
Positive (+) Weld Output
Terminal
Remote 14 Receptacle
Ref. ST-802 650
Single-Phase
460
230
15.8
40.2
25
60
14
8
139 (42)
14
10
S-0092J
400
16.9
25
14
153 (47)
14
S-0092J
OM-2222 Page 21