4-16. Factory Parameter Defaults And Range And Resolution
Parameter
MEMORY
*POLARITY
PROCESS
OUTPUT
**RMT 2T
A MAIN / PEAK
*AC TIG
*AC STICK
DC TIG
DC STICK
Spot Time
***Weld Time
PULSER
PPS
PEAK t
BKGND A
SEQUENCER
INITIAL A
***Initial Time
INITIAL SLOPE t
FINAL SLOPE t
FINAL A
***Final Time
ADJUST
PREFLOW
POST FLOW
DIG
*AC WAVESHAPE
BALANCE
FREQUENCY
OM-2222 Page 34
Default
1
DC
TIG HF Impulse
RMT STD
2T
RMT 2T can be reconfigured for: 2T / 4T / Mini Logic
/ 4T Momentary / Spot (see Section 4-19C)
150 A
110 A
150 A
110 A
1.0 S
0 S
Off
100 Hz
40%
50%
20 A
0 S
0 S
0 S
5 A
0 S
0.2 S
10.0 S
0.0 – 50.0 Seconds @ 0.2 Second Resolution
30%
75%
120 Hz
Range And Resolution
1–4
AC / DC
TIG HF Impulse / TIG Lift / Stick
RMT STD / RMT 2T / ON
5 – 300 Amps
5 – 300 Amps
5 – 300 Amps
5 – 300 Amps
0.1 – 25.0 Seconds
Dual Range And Resolution
0.0 – 99.9 / 100 – 999 Seconds
ON / OFF
Dual Range And Resolution
0.1 – 9.9 / 10 – 500 Hertz
5 – 95 Percent
5 – 95 Percent
5 – 300 Amps
0.0 – 25.0 Seconds
0.0 – 25.0 Seconds
0.0 – 25.0 Seconds
5 – 300 Amps
0.0 – 25.0 Seconds
0.0 – 25.0 Seconds
0 – 100 Percent
30 – 99 Percent
20 – 250 Hertz