Setting Force Control And Contact Reverse - Genie GCL-LJ Series Manual

Light duty jackshaft operator
Table of Contents

Advertisement

PROGRAMMING FORCE PROFILE & CONTACT REVERSE
!
IMPORTANT NOTICE
THIS STEP MUST BE PERFORMED FOR PROPER
OPERATION!
• Operate operator 2 full cycles up and down to set
new operator profile.
WARNING
!
• TO AVOID INJURY OR DAMAGE
• NEVER adjust the force settings to adjust for damage,
including an unbalanced door, binding door track or
broken spring.
• Perform a CONTACT REVERSE TEST monthly.
AVERTISSEMENT
!
• Pour éviter les blessures ou des dommages
• NE JAMAIS régler la force pour compenser des
dommages, y compris une porte mal équilibrée, un rail
de porte coinçant ou des ressorts cassés.
• Tous les mois, EFFECTUEZ LE TEST D'INVERSION AU
CONTACT.
SETTING FORCE PROFILE
1. Press and release the wall control button and allow the
garage door to travel and stop at the DOWN limit.
2. Press and release the wall control button and allow the
garage door to travel and stop at the UP limit.
3. Repeat steps 1 and 2 to complete this setting.
OPEN
CLOSE
STOP
Force Control Adjustments
Force settings are programmed from the factory to remain within
safe parameters. These should not require adjustments. However,
certain circumstances may require adjustment.
Refer to page 32 to adjust the force settings.
28
Contact Reverse Test
!
NOTE: The limit and force settings MUST BE COMPLETED before performing
the Contact Reverse Test.
1. With the garage door open, lay a 2" X 4" board flat on the
floor at the center of the door opening.
2. Close the garage door using the wall control.
• When the door contacts the board, it should stop and
reverse direction within 2 seconds to the full open
position.
• The long LED light on the powerhead will begin to flash
red with the reversal of the door.
• Remove the 2" x 4" board and operate the operator with
the wall control again. This cycle will clear the flashing red
LEDs.
Contact Reverse Adjustment
If the door stops before contacting the board or if it does not
reverse direction to fully open after contact with the board, it may
be due to an improperly set DOWN limit. Verify settings by:
1. Repeat "Programming the Down Limit" section to make
certain the door is closing tight against the floor.
2. Repeat the "Force Control" section on the left to set force
limits.
3. Repeat the "Contact Reverse Test" above.
4. Repeat this process as needed until the door passes the
contact reverse test.
Refer to page 32 to adjust the force settings.
OPEN
CLOSE
STOP

Advertisement

Table of Contents
loading

This manual is also suitable for:

Opgldj0011

Table of Contents